Vacuum valve system

remove the plug of M16 accessory 

port from the housing

remove the cap from the vacuum 

valve

slightly lubricate the o-ring and 

make sure the o-ring is in place

then tighten the vacuum valve to 

the housing with the tool provided

connect hand pump to the valve 

and pump several times until it 

reaches the target vacuum level 

close vacuum valve cap

It is recommended to leave the housing 

for at least 20mins to ensure it is sealed. 

If the LED light changes from steady 

green light to rapidly flashing yellow light, 

that means there is a leakage. Please 

check every O-ring and then conduct the 

vacuum test again.

hand pump

moisture alarm 

window

accesory port

on housing

vacuum valve

1

2

Moisture alarm window colour indication :

Steady Blue

Flashing Blue

Steady Green

Steady Red

Flashing Yellow

Flashing Red

Alternating 

Blue and Red

device is turned on
standby mode,

ready for pumpng

target vacuum level

is reached

out of battery

vacuum level

is dropping

vacuum is totally lost,

circuit stalled untill 

device is switched off

vacuum is totally lost,

circuit stalled untill 

device is switched off

* drawings as illustrations only

OPTIONAL ACCESSORIES

  

*

 please contact our authorized service centers if testing fails 

Summary of Contents for NA-R6II

Page 1: ...17339 Introduction 2 2 3 4 7 8 Package Contents Important Instructions Part Names and Functions Housing Mount Opening the housing 9 Closing the housing 10 15 Preparation for Use Optional Accessories...

Page 2: ...the included items listed below before using this product If some items are missing or damaged contact your local Nauticam dealer After purchase we suggest that you reuse all packaging materials for f...

Page 3: ...are supervised and or given instruction by a responsible person concerning use of the product to ensure that they can use it safely Do not seal the housing when travelling by air as this may lead to...

Page 4: ...n Quick control button Multi selector Up AE lock button Multi selector Right Info button Set button 1 2 3 4 5 7 9 11 13 15 17 19 16 18 6 8 10 12 14 Rear View 3 4 1 2 9 6 5 8 7 10 14 12 15 13 Quick con...

Page 5: ...M10 Accessory port Accessory mounting ball 1 4 Threaded holes Main switch Preview button Still photo shooting movie recording switch Rear dial Optical fiber cable connection 1 5 9 13 2 6 10 14 3 7 11...

Page 6: ...Port locking lever REC lever M Fn lever Front dial 1 4 Threaded tripod holes Playback lever AF ON lever Housing unlock button Shutter release lever Zoom Focus knob M5 Threaded holes Port lock safety...

Page 7: ...r Canon system Canon hotshoe plug to a M14 Nikonos bulkhead x and ground connection only 1 M10 Accessory port 1 4 20 mounting threads M24 Accessory port 3 4 5 25033 25081 25086 25077 Standard HDMI bul...

Page 8: ...THE HOUSING drawings as illustrations only 1 2 3 depress housing unlock button turn housing lock latch anti clockwise to open the housing flip open the back housing when lock latch is aligned to open...

Page 9: ...cate the main O ring make sure nothing is caught between front and back housing and that they are fully aligned before locking main O ring insert the housing shaft into the shaft hole and then rotate...

Page 10: ...camera tray by tightening the tray screw into the tripod socket of the camera place the actuator on the camera tray in place and make sure it is en gaged with the focus mode swtich on the camera lift...

Page 11: ...unting 1 2 3 depress port lock safety button and rotate anti clockwise lubricant the port O ring before mounting align index mark push port assembly straight in rotate locking lever clockwise to lock...

Page 12: ...ing an O ring remover clean the O ring groove with a cloth and ensure that it is free from salt or other foreign materials lightly coat it with provided lubricant return the main O ring by slowly pres...

Page 13: ...refer to page 15 for complete vacuum system guidance 1 3 2 4 remove battery insulation film switch on the alarm the moisture alarm window will flash in BLUE when it is working correctly test the alar...

Page 14: ...essure before unlocking port lock If using without vacuum valve please follow from step 2 unlock port lock and remove port assembly press the blue button to reset vacuum alarm before replacing port re...

Page 15: ...flashing yellow light that means there is a leakage Please check every O ring and then conduct the vacuum test again hand pump moisture alarm window accesory port on housing vacuum valve 1 2 Moisture...

Page 16: ...ignment pins with the LCD display window and push the viewfinder into the housing until it cannot go in any further gently push the 0 66x viewfinder from the inside of the housing lightly lubricate th...

Page 17: ...not travel with camera inside housing Operate all controls and buttons at least 3 times while immersed in fresh water We recommand cleaning and inspecting the main O ring each time after diving for an...

Page 18: ...d service center s Please note that this warranty only applies when the product is pur chased in the territory where the service center is lo cated NAUTICAM accepts no liability for any damage to and...

Page 19: ...inium Float Arm Buoyancy 720g 72233 Single Bayonet Holder II for 70 Float Arm 72244 Double Bayonet Holder II for 90 Float Arm 72234 Double Bayonet Holder II for 70 Float Arm 83252 Bayonet Holder for A...

Page 20: ...16 thread 25081 M24 M16 Step Down Adaptor Monitor options 1 4 17923 NA Shinobi H Housing for Atomos Shinobi 5 2 4K HDMI Monitor 17925 NA 503 H Housing for SmallHD 503 UltraBright On Camera Monitor 250...

Page 21: ...Nauticam Internationl Ltd Rm 2203 CCT Telecom Bldg 11 Wo Shing St Fo Tan Hong Kong Tel 852 26902711 Fax 852 26909778 URL www nauticam com Gallery www nauticam smugmug com...

Reviews: