Nautel ND500II Installation And Operating Instructions Manual Download Page 4

 

Dual ND500II (User Supplied Cabinet) – IS03003

 

Page 3

 

Information Sheet 

Issue 1.0

 

(e) 

Install the cable harness (Nautel Part 
# 158-8202) into the cabinet as 
follows: 

 

-

 

Remove transmitter (A and B) rear 
covers.  Retain hardware to re-install 
cover. 

 

-

 

Terminate the connectors on 
transmitter A as follows: 

 
 

Connect BNC connector P5 to A11J3 

 

Connect D connector P6 to A11J4 

 

Connect N connector P7 to A7J3 

 

Connect wire # 45 to A11TB2-1 

 

Connect wire # 46 to A11TB2-2 

 

-

 

Make the following connections if the 
cabinet’s output connector is located 
near cabinet lower right hand side: 

 

 

Connect P10 to A7J2  

 

Connect wire # 44 (core) to cabinet’s 
RF output connector (center 
conductor) 

 

Connect wire # 44 (shield) to cabinet’s 
RF output connector (shield) 
If cabinet’s output connector is not 
located near the cabinet’s lower right 
hand side, do not terminate P10 or 
wire # 44.  Secure these wire ends to 
the cable harness. 

 

Terminate the connectors on 
transmitter B as follows: 

 

Connect D connector P8 to A11J4 

 

Connect BNC connector P9 to A11J3 

 

Connect N connector P11 to A7J2 

 

Connect wire # 47 to A11TB2-1 

 

Connect wire # 48 to A11TB2-2 

 

Terminate the connectors on dual 
transmitter interface assembly as 
follows: 

 

Connect D connector P3 to A1J5 

 

Connect D connector P2 to A1J4 

 

Connect BNC connector P1 to A1J7 

 

Connect BNC connector P4 to A1J6 

 

Connect wire # 45 to A1TB4-3 

 

Connect wire # 46 to A1TB4-4 

 

Connect wire # 47 to A1TB4-3 

 

Connect wire # 48 to A1TB4-4 

 

Secure the cableform to the cabinet to 
ensure the transmitters can be pulled 
out on their slides and no wiring in the 
cable can be pinched. 

 
(f) 

If the computer remote control option 
is installed, install cable harness 
Nautel Part # 158-8212 as follows: 

 

Terminate the connectors on the 
remote control assembly as follows: 

 
 

Connect D connector P13 to A1J4 

 

Connect wire 101 to TB1-1 

 

Connect wire 103 to TB1-2 

 

Terminate the connectors on the dual 
transmitter interface assembly as 
follows: 

 

Connect D connector P12 to A1J1 

 
(g) 

Install the dual transmitter interface 
assembly in the cabinet using the four 
front panel mounting holes. 

 
(h) 

Install the remote control unit in the 
cabinet using the four front panel 
mounting holes. 

 
(i) 

Install the safety ground wiring using 
green/yellow wire and lugs provided in 
‘Safety Ground Wire Kit’ (Nautel Part # 
158-8226) as follows: 

 

Transmitter A safety ground (located 
at rear of transmitter) to cabinet safety 
ground. 

 

Transmitter B safety ground (located 
at rear of transmitter) to cabinet safety 
ground. 

 

NOTE 

A cabinet safety ground should be located 
near the RF output connector of the cabinet 
to help protect equipment from lightning 
damage.  

 
(j) 

Connect AC line cords to transmitter A 
and B.  Termination is made at 
transmitter rear. 

 

Summary of Contents for ND500II

Page 1: ...autel Limited 10089 Peggy s Cove Road Hackett s Cove NS Canada B3Z 3J4 T 1 902 823 2233 F 1 902 823 3183 info nautel com U S customers please contact Nautel Maine Inc 201 Target Industrial Circle Bang...

Page 2: ...th transmitters A ND500II 11x x2x and B ND500II 01x x2x The following provides a brief description for transmitters that are connected in a main standby dual installation See figure 2A or 2B for inter...

Page 3: ...by transmitter is on g If transmitter B is selected as the main transmitter an open collector SHTDN ALM B signal will be applied to 3A1J5 23 from A11J4 17 shutdown of transmitter B causing a ground to...

Page 4: ...onnect BNC connector P1 to A1J7 Connect BNC connector P4 to A1J6 Connect wire 45 to A1TB4 3 Connect wire 46 to A1TB4 4 Connect wire 47 to A1TB4 3 Connect wire 48 to A1TB4 4 Secure the cableform to the...

Page 5: ...of transmitter A o Re install rear covers on transmitters A and B that were removed in step e 5 INITIAL START UP PROCEDURES Transmitters A and B should not be fully operated as a dual transmitter sys...

Page 6: ...e harness and should not be used for connection between transmitter B and an external dummy load A user provided coaxial cable should be obtained f Set transmitter B s LOCAL REMOTE switch to LOCAL g S...

Page 7: ...ginal connections p Remove jumper connected in step c q Set POWER switch of both transmitters to ON and set their LOCAL REMOTE switches to the desired position 7 CHECK OF CHANGEOVER UNIT Check the ope...

Page 8: ...C is used as voltage source for external SWR ALARM and BATTERY STATUS circuits connect circuit VDC to 3A1TB2 8 3A1J1 2 If an external DC power supply is used as voltage source for external SWR ALARM a...

Page 9: ...3 P2 11 14 White 22 P6 14 P2 7 15 White 22 1 Conductor P6 15 P2 19 15 Shield 22 Shielded P6 16 P2 8 16 Black 22 P6 17 P2 23 17 White 22 P6 18 P2 9 18 White 22 P6 19 P2 6 19 White 22 P6 20 P2 2 20 Whit...

Page 10: ...49 Grn Yel 14 User Cabinet Safety Ground 2 Safety Ground 50 Grn Yel 14 Additional wiring when remote control unit unit 4 is used P12 3 P13 36 100 White 22 P12 4 4TB1 1 101 White 22 P12 5 P13 24 102 Wh...

Page 11: ...m Crimp JDP24 225395 7 09482 P2 Connector D Sub 25 Socket 183 5010 183 5010 37338 P3 Connector D Sub 25 Socket 183 5010 183 5010 37338 P4 Connector Coaxial BNC Plug 50ohm Crimp JDP24 225395 7 09482 P5...

Page 12: ...PWB JS43 163A16279X 31781 J6 Connector BNC Receptacle PWB Mt JF35 R141 426 000 0GP12 J7 Connector BNC Receptacle PWB Mt JF35 R141 426 000 0GP12 J8 Conn Socket D Sub 9 Pin Vertical PWB JS50 164A16669X...

Page 13: ...14 19 16 15 A7J2 P11 2 17 1 XMTR A A11J4 5 9 7 6 1 1 18 A11J4 8 INCREASE A DECREASE A 15VDC ATU A GND A SERVO INHB A RMT SHTDN ALM A B VDC A 24VDC A RMT SWR ALM A 13 23 9 24 15 16 17 1 14 GND A RMT AU...

Page 14: ...ION 1 GND A DC SUPPLY DC SUPPLY 1 2 A11TB2 22 12 20 21 3 4 A11J4 XMTR A RMT ON OFF A RMT PWR TRIM A STBY ON OFF A STBY 2 A STBY 1 A A11J4 1 7 9 6 RMT SHTDN ALM A DECREASE A 15VDC ATU A GND A SERVO INH...

Page 15: ...R5 1 13 J1 1 16 K1 E 3 5 7 K1 A 1 12 J1 1 16 K2 E CR6 3 5 7 K2 A 13 11 9 K1 C 4 6 8 K1 B 1 2 RMT XMTR ON STAT 9 4 J1 B VDC 1 2 3 NO COM NC RMT SHTDN ALM 3 J1 19 J1 6 15VDC B STBY ON OFF A 2 J4 RMT ON...