Nautel ND500II Installation And Operating Instructions Manual Download Page 13

 

Dimensions = mm (inches) 

Figure 2A - Electrical Schematic - Dual ND500II Transmitter System (User 
Supplied Cabinet, no Remote Control Unit) 

Version 1.0 

Not to Scale 

Drawing No. S1580200 

Sheet 1 of 1 

 

 

 

 

STBY 1 (A)

RMT PWR TRIM (B)

STBY 1 (B)

STBY 2

GND

23 J1

3

4

P4

J6

DENOTES TB1

DENOTES TB2

DENOTES TB3

DENOTES TB4

S1580200  V1

25 J1

1

11

1

P3

2

24 J1

J5

5

2

22 J1

4

3

8

16 J1

RMT PWR TRIM (B)

STBY ON/OFF (B)

GROUND

STBY 1 (B)

STBY 2 (B)

RMT ON/OFF (B)

GND (B)

4

21

22

3

12

20

P8

EXT RF INPUT (B)

A11J3

P9

AC POWER

SOURCE

(XMTR B)

LINE

NEUTRAL

GROUND

DENOTES TB6

EXT RF INPUT (B)

EXT RF INPUT (A)

RMT ON/OFF

DC SUPPLY

RMT PWR TRIM (A)

RMT B MAIN

3A1

PART OF

EXT RF INPUT (A)

AC POWER

SOURCE

(XMTR A)

LINE

NEUTRAL

GROUND

17 J1

6

3

4

2

4

10 J1

-

11 J1

+

4

3

J3

1

3

5

J2

J4

DUAL XMTR

INTERFACE

PWB

P2

P1

10

21

2

J7

STBY 1 (A)

RMT ON/OFF (A)

RMT PWR TRIM (A)

STBY ON/OFF (A)

STBY 2 (A)

GND (A)

DC SUPPLY (+)

3

22

4

21

20

12

P6

A11J3

P5

SAFETY

LIGHTNING/

STATION

DC SUPPLY (-)

A7J3

P7

*

A11TB2

2

14

19

16

15

A7J2

P11

2

17

1

XMTR A

A11J4

5

9

7

6

1

1

18

A11J4

8

INCREASE (A)

DECREASE (A)

+15VDC ATU (A)

GND (A)

SERVO INHB (A)

RMT SHTDN ALM (A)

B+VDC (A)

+24VDC (A)

RMT SWR ALM (A)

13

23

9

24

15

16

17

1

14

GND (A)

RMT AUDIO (A)

RMT BTRY STAT (A)

19

8

6

7

11

13

A7J2

P10

U2

P6

GND (A)

+15VDC (A)

11

20

P2

DENOTES PART OF USER-SUPPLIED CABINET.

IF 'RF OUT' CONNECTOR IS NOT PRESENT, P10 IS

REMOVED AND 1A7J2 BECOMES SYSTEM'S 'RF OUT'.

*

1

J1

RMT AUDIO

20

J1

5

RMT AUDIO GND

PART OF

3A1

DUAL XMTR

RF OUT

2

J1

9

8

+15VDC (A)

PWB

INTERFACE

*

5

J1

6

6

J1

GND

7

J1

+15VDC (B)

7

6

8

J1

RMT CHGOV ALM

8

RMT SWR ALM

9

4

J1

3

J1

7

J4

14

J1

19

J1

+24VDC (B)

9

15

J1

B+ VDC

+24VDC (A)

15

14

U2

A11J4

2

17

19

16

1

18

A11J4

5

7

6

9

2

1

A11TB2

XMTR B

2

11

13

8

P8

GND (B)

INCREASE (B)

DECREASE (B)

+15VDC (B)

+15VDC ATU (B)

SERVO INHB (B)

GND (B)

RMT SHTDN ALM (B)

18

16

17

14

9

19

15

P3

RMT AUDIO (B)

B+VDC (B)

+24VDC (B)

GND (B)

RMT SWR ALM (B)

RMT BTRY STAT (B)

6

22

10

20

25

23

7

8

INCREASE

4

J8

1

J8

+15VDC ATU

7

J5

1

5

ATU CONTROL

GND

5

J8

6

J8

4

RMT SHTDN ALM

GND

13

J1

18

J1

1

9

J1

5

RMT BTRY STAT

12

J1

RMT XMTR ON STAT

2

7

J8

2

3

DECREASE

SERVO INHB

NO

COM

NC

RMT SHTDN ALM

NO

COM

NC

RMT CHGOV ALM

5

4

6

3

2

1

Summary of Contents for ND500II

Page 1: ...autel Limited 10089 Peggy s Cove Road Hackett s Cove NS Canada B3Z 3J4 T 1 902 823 2233 F 1 902 823 3183 info nautel com U S customers please contact Nautel Maine Inc 201 Target Industrial Circle Bang...

Page 2: ...th transmitters A ND500II 11x x2x and B ND500II 01x x2x The following provides a brief description for transmitters that are connected in a main standby dual installation See figure 2A or 2B for inter...

Page 3: ...by transmitter is on g If transmitter B is selected as the main transmitter an open collector SHTDN ALM B signal will be applied to 3A1J5 23 from A11J4 17 shutdown of transmitter B causing a ground to...

Page 4: ...onnect BNC connector P1 to A1J7 Connect BNC connector P4 to A1J6 Connect wire 45 to A1TB4 3 Connect wire 46 to A1TB4 4 Connect wire 47 to A1TB4 3 Connect wire 48 to A1TB4 4 Secure the cableform to the...

Page 5: ...of transmitter A o Re install rear covers on transmitters A and B that were removed in step e 5 INITIAL START UP PROCEDURES Transmitters A and B should not be fully operated as a dual transmitter sys...

Page 6: ...e harness and should not be used for connection between transmitter B and an external dummy load A user provided coaxial cable should be obtained f Set transmitter B s LOCAL REMOTE switch to LOCAL g S...

Page 7: ...ginal connections p Remove jumper connected in step c q Set POWER switch of both transmitters to ON and set their LOCAL REMOTE switches to the desired position 7 CHECK OF CHANGEOVER UNIT Check the ope...

Page 8: ...C is used as voltage source for external SWR ALARM and BATTERY STATUS circuits connect circuit VDC to 3A1TB2 8 3A1J1 2 If an external DC power supply is used as voltage source for external SWR ALARM a...

Page 9: ...3 P2 11 14 White 22 P6 14 P2 7 15 White 22 1 Conductor P6 15 P2 19 15 Shield 22 Shielded P6 16 P2 8 16 Black 22 P6 17 P2 23 17 White 22 P6 18 P2 9 18 White 22 P6 19 P2 6 19 White 22 P6 20 P2 2 20 Whit...

Page 10: ...49 Grn Yel 14 User Cabinet Safety Ground 2 Safety Ground 50 Grn Yel 14 Additional wiring when remote control unit unit 4 is used P12 3 P13 36 100 White 22 P12 4 4TB1 1 101 White 22 P12 5 P13 24 102 Wh...

Page 11: ...m Crimp JDP24 225395 7 09482 P2 Connector D Sub 25 Socket 183 5010 183 5010 37338 P3 Connector D Sub 25 Socket 183 5010 183 5010 37338 P4 Connector Coaxial BNC Plug 50ohm Crimp JDP24 225395 7 09482 P5...

Page 12: ...PWB JS43 163A16279X 31781 J6 Connector BNC Receptacle PWB Mt JF35 R141 426 000 0GP12 J7 Connector BNC Receptacle PWB Mt JF35 R141 426 000 0GP12 J8 Conn Socket D Sub 9 Pin Vertical PWB JS50 164A16669X...

Page 13: ...14 19 16 15 A7J2 P11 2 17 1 XMTR A A11J4 5 9 7 6 1 1 18 A11J4 8 INCREASE A DECREASE A 15VDC ATU A GND A SERVO INHB A RMT SHTDN ALM A B VDC A 24VDC A RMT SWR ALM A 13 23 9 24 15 16 17 1 14 GND A RMT AU...

Page 14: ...ION 1 GND A DC SUPPLY DC SUPPLY 1 2 A11TB2 22 12 20 21 3 4 A11J4 XMTR A RMT ON OFF A RMT PWR TRIM A STBY ON OFF A STBY 2 A STBY 1 A A11J4 1 7 9 6 RMT SHTDN ALM A DECREASE A 15VDC ATU A GND A SERVO INH...

Page 15: ...R5 1 13 J1 1 16 K1 E 3 5 7 K1 A 1 12 J1 1 16 K2 E CR6 3 5 7 K2 A 13 11 9 K1 C 4 6 8 K1 B 1 2 RMT XMTR ON STAT 9 4 J1 B VDC 1 2 3 NO COM NC RMT SHTDN ALM 3 J1 19 J1 6 15VDC B STBY ON OFF A 2 J4 RMT ON...

Page 16: ...Dimensions mm inches Figure 4 Assembly Detail Dimensional Information Dual ND500II Transmitters User Supplied Cabinet Version 1 0 Not to Scale Drawing No M1580198 Sheet 1 of 1...

Page 17: ...Dimensions mm inches Figure 5 Assembly Detail NAX223 Dual Transmitter Interface Assembly Version 1 0 Not to Scale Drawing No M1580191 Sheet 1 of 1...

Page 18: ...Dimensions mm inches Figure 6 Assembly Detail NAPI66 Dual Transmitter Interface PWB Version 1 0 Not to Scale Drawing No M1580175 Sheet 1 of 1...