Nautel ND500II Installation And Operating Instructions Manual Download Page 12

 

Dual ND500II (User Supplied Cabinet) – IS03003

 

Page 11

 

Information Sheet 

Issue 1.0

 

 

Table 3 - Reference Designation Index – NAPI66 Dual Transmitter Interface PWB 

 

USE 
CODE 

REF 
DES 

NAME OF PART 
AND DESCRIPTION 

NAUTEL 
PART NO. 

JAN/MIL/OEM 

PART NO. 

OEM 

CODE 

 

 

 

 

 

 

 

Dual ND500II Interface PWB 

NAPI66 

158-4010 

37338 

 

CR1 

Diode, Power Rectifier, 200V , 3A 

QG31 

1N5624 

89473 

 

CR2 

Diode, Power Rectifier, 200V , 3A 

QG31 

1N5624 

89473 

 

CR3 

Diode, Power Rectifier, 200V , 3A 

QG31 

1N5624 

89473 

 

CR4 

Diode, Power Rectifier, 200V , 3A 

QG31 

1N5624 

89473 

 

CR5 

Diode, General Purpose, 200V, 0.1A 

QAP29 

1N4938 

07263 

 

CR6 

Diode, General Purpose, 200V, 0.1A 

QAP29 

1N4938 

07263 

 

CR7 

Diode, General Purpose, 200V, 0.1A 

QAP29 

1N4938 

07263 

 

CR8 

Diode, General Purpose, 200V, 0.1A 

QAP29 

1N4938 

07263 

 

J1 

Connector, Socket, D-Sub, 25 Pin, 

Vertical Mt. 

JS49 164A16689X 

18310 

 

J2 

Connector, BNC, Receptacle, PWB Mt 

JF35 

R141.426.000 

0GP12 

 

J3 

Connector, BNC, Receptacle, PWB Mt 

JF35 

R141.426.000 

0GP12 

 

J4 

Conn, Plug, D-Sub, 25 pin, Vertical PWB 

JS43 

163A16279X 

31781 

 

J5 

Conn, Plug, D-Sub, 25 pin, Vertical PWB 

JS43 

163A16279X 

31781 

 

J6 

Connector, BNC, Receptacle, PWB Mt 

JF35 

R141.426.000 

0GP12 

 

J7 

Connector, BNC, Receptacle, PWB Mt 

JF35 

R141.426.000 

0GP12 

 

J8 

Conn, Socket, D-Sub, 9-Pin, Vertical 

PWB 

JS50 164A16669X 

C3057 

 

K1 

Relay, 24V, 4PDT, PWB Mount 

KC11 

DS4E-M-DC24V 

61529 

 

K2 

Relay, 24V, 4PDT, PWB Mount 

KC11 

DS4E-M-DC24V 

61529 

 

K3 

Relay, 24V, 4PDT, PWB Mount 

KC11 

DS4E-M-DC24V 

61529 

 

K4 

Relay, 24V, 2PDT, 1A, PWB Mount 

KC06 

DF2E-DC24V 

61529 

 

S1 

Switch, Rocker, SPDT, ON-ON 

SD58 

M2T12TXW13-DA 

63426 

 

S2 

Switch, Rocker, SPDT, ON-ON 

SD58 

M2T12TXW13-DA 

63426 

 

TB1 

Terminal Block, 9 Positions 

161-3023-09 

161-3023-09 

37338 

 

TB2 

Terminal Block, 9 Positions 

161-3023-09 

161-3023-09 

37338 

 

TB3 

Terminal Block, 9 Positions 

161-3023-09 

161-3023-09 

37338 

 

TB4 

Terminal Block, 4 Positions, Sgl, Ins Tur, 

20A 

JR11 387403104 13150 

 

TB5 

Terminal Block, 3 Positions 

161-3023-03 

161-3023-03 

37338 

 

TB6 

Terminal Block, 6 Positions 

161-3023-06 

161-3023-06 

37338 

 

XE1 

Header, Shunt Post, 3 Pin 

161-3008-03 

161-3008-03 

37338 

 XK1 

Socket, 

Relay 

163-5003-01 

163-5003-01 37338 

 XK2 

Socket, 

Relay 

163-5003-01 

163-5003-01 37338 

 XK3 

Socket, 

Relay 

163-5003-01 

163-5003-01 37338 

 XK4 

Socket, 

Relay 

163-5003 

163-5003 

37338 

 

 

 

 

 

 

 
NOTE: 

Prefix with 3A1 to obtain item’s full reference designation.

 

Summary of Contents for ND500II

Page 1: ...autel Limited 10089 Peggy s Cove Road Hackett s Cove NS Canada B3Z 3J4 T 1 902 823 2233 F 1 902 823 3183 info nautel com U S customers please contact Nautel Maine Inc 201 Target Industrial Circle Bang...

Page 2: ...th transmitters A ND500II 11x x2x and B ND500II 01x x2x The following provides a brief description for transmitters that are connected in a main standby dual installation See figure 2A or 2B for inter...

Page 3: ...by transmitter is on g If transmitter B is selected as the main transmitter an open collector SHTDN ALM B signal will be applied to 3A1J5 23 from A11J4 17 shutdown of transmitter B causing a ground to...

Page 4: ...onnect BNC connector P1 to A1J7 Connect BNC connector P4 to A1J6 Connect wire 45 to A1TB4 3 Connect wire 46 to A1TB4 4 Connect wire 47 to A1TB4 3 Connect wire 48 to A1TB4 4 Secure the cableform to the...

Page 5: ...of transmitter A o Re install rear covers on transmitters A and B that were removed in step e 5 INITIAL START UP PROCEDURES Transmitters A and B should not be fully operated as a dual transmitter sys...

Page 6: ...e harness and should not be used for connection between transmitter B and an external dummy load A user provided coaxial cable should be obtained f Set transmitter B s LOCAL REMOTE switch to LOCAL g S...

Page 7: ...ginal connections p Remove jumper connected in step c q Set POWER switch of both transmitters to ON and set their LOCAL REMOTE switches to the desired position 7 CHECK OF CHANGEOVER UNIT Check the ope...

Page 8: ...C is used as voltage source for external SWR ALARM and BATTERY STATUS circuits connect circuit VDC to 3A1TB2 8 3A1J1 2 If an external DC power supply is used as voltage source for external SWR ALARM a...

Page 9: ...3 P2 11 14 White 22 P6 14 P2 7 15 White 22 1 Conductor P6 15 P2 19 15 Shield 22 Shielded P6 16 P2 8 16 Black 22 P6 17 P2 23 17 White 22 P6 18 P2 9 18 White 22 P6 19 P2 6 19 White 22 P6 20 P2 2 20 Whit...

Page 10: ...49 Grn Yel 14 User Cabinet Safety Ground 2 Safety Ground 50 Grn Yel 14 Additional wiring when remote control unit unit 4 is used P12 3 P13 36 100 White 22 P12 4 4TB1 1 101 White 22 P12 5 P13 24 102 Wh...

Page 11: ...m Crimp JDP24 225395 7 09482 P2 Connector D Sub 25 Socket 183 5010 183 5010 37338 P3 Connector D Sub 25 Socket 183 5010 183 5010 37338 P4 Connector Coaxial BNC Plug 50ohm Crimp JDP24 225395 7 09482 P5...

Page 12: ...PWB JS43 163A16279X 31781 J6 Connector BNC Receptacle PWB Mt JF35 R141 426 000 0GP12 J7 Connector BNC Receptacle PWB Mt JF35 R141 426 000 0GP12 J8 Conn Socket D Sub 9 Pin Vertical PWB JS50 164A16669X...

Page 13: ...14 19 16 15 A7J2 P11 2 17 1 XMTR A A11J4 5 9 7 6 1 1 18 A11J4 8 INCREASE A DECREASE A 15VDC ATU A GND A SERVO INHB A RMT SHTDN ALM A B VDC A 24VDC A RMT SWR ALM A 13 23 9 24 15 16 17 1 14 GND A RMT AU...

Page 14: ...ION 1 GND A DC SUPPLY DC SUPPLY 1 2 A11TB2 22 12 20 21 3 4 A11J4 XMTR A RMT ON OFF A RMT PWR TRIM A STBY ON OFF A STBY 2 A STBY 1 A A11J4 1 7 9 6 RMT SHTDN ALM A DECREASE A 15VDC ATU A GND A SERVO INH...

Page 15: ...R5 1 13 J1 1 16 K1 E 3 5 7 K1 A 1 12 J1 1 16 K2 E CR6 3 5 7 K2 A 13 11 9 K1 C 4 6 8 K1 B 1 2 RMT XMTR ON STAT 9 4 J1 B VDC 1 2 3 NO COM NC RMT SHTDN ALM 3 J1 19 J1 6 15VDC B STBY ON OFF A 2 J4 RMT ON...

Page 16: ...Dimensions mm inches Figure 4 Assembly Detail Dimensional Information Dual ND500II Transmitters User Supplied Cabinet Version 1 0 Not to Scale Drawing No M1580198 Sheet 1 of 1...

Page 17: ...Dimensions mm inches Figure 5 Assembly Detail NAX223 Dual Transmitter Interface Assembly Version 1 0 Not to Scale Drawing No M1580191 Sheet 1 of 1...

Page 18: ...Dimensions mm inches Figure 6 Assembly Detail NAPI66 Dual Transmitter Interface PWB Version 1 0 Not to Scale Drawing No M1580175 Sheet 1 of 1...