Table 1 - Wiring List – Dual ND500II Transmitters (Cont.) 
 

SOURCE DESTINATION 

CODE SIZE 

REMARKS 

 

 

 

 

 

 

P7-Centre P11-Centre 

43 

Core  RG58A/U 

Coaxial 

Cable 

P7-Body P11-Body 

43 

Shield 

 

P10-Centre 

RF Output-Centre 

44 

Core 

RG58A/U 

Coaxial Cable 

P10-Body Safety 

Ground 

44 

Shield - 

 

3A1TB4-3 1A11TB2-1 

45 

White 10 

 

3A1TB4-4 1A11TB2-2 

46 

Black  10 

 

3A1TB4-3 2A11TB2-1 

47 

White 10 

 

3A1TB4-4 2A11TB2-2 

48 

Black  10 

 

User Cabinet -
Safety Ground 

1-Safety Ground 

49 

Grn/Yel 

14 

 

User Cabinet -
Safety Ground 

2-Safety Ground 

50 

Grn/Yel 

14 

 

Additional wiring when remote control unit (unit 4) is used:

 

 

 

 

 

 

 

P12-3 P13-36 

100 

White 

22 

 

P12-4 4TB1-1 

101 

White 

22 

 

P12-5 P13-24 

102 

White 

22 

 

P12-6 4TB1-2 

103 

Black 

22 

 

P12-7 P13-18 

104 

Black 

22 

 

P12-8 P13-21 

105 

White 

22 

 

P12-9 P13-26 

106 

White 

22 

 

P12-12 P13-20 

107 

White 

22 

 

P12-13 P13-25 

108 

White 

22 

 

P12-11 P13-2 

109 

White 

22 

 

P12-10 P13-1 

110 

White 

22 

 

 

NOTE:

   

Destinations with a '1' prefix are located on transmitter A (upper). 

 

 

 

Destinations with a '2' prefix are located on transmitter B (lower). 

 

 

 

Destinations with a '3' prefix are located on dual transmitter interface assembly. 

 

 

 

Destinations with a '4' prefix are located on optional remote control unit. 

 
 

Summary of Contents for ND500II

Page 1: ...autel Limited 10089 Peggy s Cove Road Hackett s Cove NS Canada B3Z 3J4 T 1 902 823 2233 F 1 902 823 3183 info nautel com U S customers please contact Nautel Maine Inc 201 Target Industrial Circle Bang...

Page 2: ...th transmitters A ND500II 11x x2x and B ND500II 01x x2x The following provides a brief description for transmitters that are connected in a main standby dual installation See figure 2A or 2B for inter...

Page 3: ...by transmitter is on g If transmitter B is selected as the main transmitter an open collector SHTDN ALM B signal will be applied to 3A1J5 23 from A11J4 17 shutdown of transmitter B causing a ground to...

Page 4: ...onnect BNC connector P1 to A1J7 Connect BNC connector P4 to A1J6 Connect wire 45 to A1TB4 3 Connect wire 46 to A1TB4 4 Connect wire 47 to A1TB4 3 Connect wire 48 to A1TB4 4 Secure the cableform to the...

Page 5: ...of transmitter A o Re install rear covers on transmitters A and B that were removed in step e 5 INITIAL START UP PROCEDURES Transmitters A and B should not be fully operated as a dual transmitter sys...

Page 6: ...e harness and should not be used for connection between transmitter B and an external dummy load A user provided coaxial cable should be obtained f Set transmitter B s LOCAL REMOTE switch to LOCAL g S...

Page 7: ...ginal connections p Remove jumper connected in step c q Set POWER switch of both transmitters to ON and set their LOCAL REMOTE switches to the desired position 7 CHECK OF CHANGEOVER UNIT Check the ope...

Page 8: ...C is used as voltage source for external SWR ALARM and BATTERY STATUS circuits connect circuit VDC to 3A1TB2 8 3A1J1 2 If an external DC power supply is used as voltage source for external SWR ALARM a...

Page 9: ...3 P2 11 14 White 22 P6 14 P2 7 15 White 22 1 Conductor P6 15 P2 19 15 Shield 22 Shielded P6 16 P2 8 16 Black 22 P6 17 P2 23 17 White 22 P6 18 P2 9 18 White 22 P6 19 P2 6 19 White 22 P6 20 P2 2 20 Whit...

Page 10: ...49 Grn Yel 14 User Cabinet Safety Ground 2 Safety Ground 50 Grn Yel 14 Additional wiring when remote control unit unit 4 is used P12 3 P13 36 100 White 22 P12 4 4TB1 1 101 White 22 P12 5 P13 24 102 Wh...

Page 11: ...m Crimp JDP24 225395 7 09482 P2 Connector D Sub 25 Socket 183 5010 183 5010 37338 P3 Connector D Sub 25 Socket 183 5010 183 5010 37338 P4 Connector Coaxial BNC Plug 50ohm Crimp JDP24 225395 7 09482 P5...

Page 12: ...PWB JS43 163A16279X 31781 J6 Connector BNC Receptacle PWB Mt JF35 R141 426 000 0GP12 J7 Connector BNC Receptacle PWB Mt JF35 R141 426 000 0GP12 J8 Conn Socket D Sub 9 Pin Vertical PWB JS50 164A16669X...

Page 13: ...14 19 16 15 A7J2 P11 2 17 1 XMTR A A11J4 5 9 7 6 1 1 18 A11J4 8 INCREASE A DECREASE A 15VDC ATU A GND A SERVO INHB A RMT SHTDN ALM A B VDC A 24VDC A RMT SWR ALM A 13 23 9 24 15 16 17 1 14 GND A RMT AU...

Page 14: ...ION 1 GND A DC SUPPLY DC SUPPLY 1 2 A11TB2 22 12 20 21 3 4 A11J4 XMTR A RMT ON OFF A RMT PWR TRIM A STBY ON OFF A STBY 2 A STBY 1 A A11J4 1 7 9 6 RMT SHTDN ALM A DECREASE A 15VDC ATU A GND A SERVO INH...

Page 15: ...R5 1 13 J1 1 16 K1 E 3 5 7 K1 A 1 12 J1 1 16 K2 E CR6 3 5 7 K2 A 13 11 9 K1 C 4 6 8 K1 B 1 2 RMT XMTR ON STAT 9 4 J1 B VDC 1 2 3 NO COM NC RMT SHTDN ALM 3 J1 19 J1 6 15VDC B STBY ON OFF A 2 J4 RMT ON...

Page 16: ...Dimensions mm inches Figure 4 Assembly Detail Dimensional Information Dual ND500II Transmitters User Supplied Cabinet Version 1 0 Not to Scale Drawing No M1580198 Sheet 1 of 1...

Page 17: ...Dimensions mm inches Figure 5 Assembly Detail NAX223 Dual Transmitter Interface Assembly Version 1 0 Not to Scale Drawing No M1580191 Sheet 1 of 1...

Page 18: ...Dimensions mm inches Figure 6 Assembly Detail NAPI66 Dual Transmitter Interface PWB Version 1 0 Not to Scale Drawing No M1580175 Sheet 1 of 1...