GV5/GV3.5 OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.2 2014-07-23
PAGE 3.2.15
Exciter
:
Displays the active exciter and the peak (red) FM modulation value. Press in the Active
Exciter field to shortcut to the
Changeover
page. The active exciter is displayed in the top, right
corner (
see
).
Forward Power
:
Displays the analog power output when in FM or FM +HD modes and displays
the HD power output when in HD (only) mode.
The bottom banner is also permanent on all AUI pages and includes the following buttons, some of
which open other menus and displays:
RF On
:
Press to enable the transmitter’s RF power stage. When the button is highlighted green, RF
is enabled (on). When the button is highlighted amber, a fault condition exists that is preventing
the RF power stage from turning on.
RF Off
:
Press to disable the transmitter’s RF power stage. When button is highlighted in red, RF is
disabled (off).
Activity Window:
Displays various messages to reflect specific user interface commands, such as
which user is logged in, if the transmitter RF is held off, etc.
Menu:
Press to open the
Menu
page, which allows navigation to various other pages (see
Page - Describing Transmitter Operations on page 3.2.25
).
Status
:
Press to open the
Transmitter Status
page (see
Viewing Transmitter Status - using the AUI
), which provides current alarm and status details for the transmitter. When the
Status
button is red, one or more alarms of “high” severity is currently being reported and the
transmitter is in an ‘off-air’ state. When the
Status
button is amber, “medium” or yellow “low”
one or more lower level alarms is currently being reported, but the transmitter is still ‘on-air’,
possibly at reduced power. When the
Status
button is green, the transmitter is operating normally.
In this case there are no alarms being reported.
Logs
:
Press to shortcut to the
Transmitter Log
page, which displays historical alarm and status
records for the transmitter (see
Viewing Transmitter Log on page 3.2.27
Local/Remote
:
Displays the operational control status of the transmitter. From the touch screen,
press the desired button. If
Local
is highlighted green, only local control of the AUI is possible. If
both
Local
and
Remote
are highlighted green, both local and remote controls are enabled.
Reset:
Press to reset protection circuits and restore any RF power modules (and associated power
supplies) that were inhibited, but are now alarm-free.
Change User/Log Out:
Press to display a login menu. Enter your username and password, then
press
Done
. If you do not have a user account, see
User Accounts, on page 3.2.130
.
Change User
button will display as
Log Out
while viewing AUI remotely.
Summary of Contents for GV5
Page 2: ......
Page 4: ......
Page 8: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 2 2014 07 23...
Page 16: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 8 VERSION 0 2 2014 07 23...
Page 18: ...VERSION 0 2 2014 07 23 PAGE 3 1 10 LJXUH 9 9 XGLR 3DWK ORFN LDJUDP...
Page 239: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL ROUTINE MAINTENANCE PAGE 3 3 10 VERSION 0 2 2014 07 23...
Page 249: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 2 2014 07 23...
Page 250: ......