GV5/GV3.5 OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.2 2014-07-23
PAGE 3.2.177
Select Output Channel - AUI
You can configure digital outputs 1 through 16 to monitor a variety of alarm and status outputs. Press
the existing
Channel
bar to display the
Select a remote
). From this
window, select one of the channels, then click
OK
to accept:
Not Assigned
. No alarm or status parameter is monitored.
Local/Remote
. The active logic level indicates the transmitter is in local control. The inactive
logic level indicates the transmitter is in remote control.
RF On/Off
. The active logic level indicates the transmitter’s RF power stage is on (enabled).
The inactive logic level indicates the transmitter’s RF power stage is off.
Preset Status
(1-3 default). The active preset’s output will be indicated by a logic low. The
remaining, non-active preset outputs will be open collector.
Active Exciter
. The active exciter’s output will be indicated by a logic low. The other, non-
active exciter output (as applicable), will be open collector.
Auto Changeover Enabled
. The active logic level indicates that auto changeover is enabled.
The inactive logic level indicates that auto changeover is disabled.
Various Alarms
. The active logic level indicates that the selected alarm is occurring. Any
transmitter alarm can be selected as a digital output. Refer to the GV5/GV3.5 Troubleshooting
Manual for a description of each alarm.
Figure 3.2.152: Select a Remote (output) window
Summary of Contents for GV5
Page 2: ......
Page 4: ......
Page 8: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 2 2014 07 23...
Page 16: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 8 VERSION 0 2 2014 07 23...
Page 18: ...VERSION 0 2 2014 07 23 PAGE 3 1 10 LJXUH 9 9 XGLR 3DWK ORFN LDJUDP...
Page 239: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL ROUTINE MAINTENANCE PAGE 3 3 10 VERSION 0 2 2014 07 23...
Page 249: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 2 2014 07 23...
Page 250: ......