Calibration
NOTE
: Most of the Calibration settings are only available using the controller UI. Calibration of audio
) can also be performed using the AUI (see
).
From the controller’s UI, you can calibrate various parameters. To view the Calibration menu (see
), select
System Settings -> Factory Settings -> Calibration
from the
Main Menu
.
Figure 3.2.112: Calibration Menu
Running the Xmtr PA Bias Routine.
You must run the transmitter’s PA bias routine immediately
after one of the following events:
installation of a new RF power module
swapping of existing RF power modules
installation of a new controller module
NOTE
: Make sure that the RF stage is disabled (RF Off) and the interlock circuit is closed before running
the PA bias routine. If not, a message will appear on the display prompting you to do so.
Use the up or down arrow to place the cursor next to
Xmtr PA Bias
, then press the accept (checkmark)
button to enter the sub-menu. Within the sub-menu, press the accept (checkmark) button to start the
routine. A line will display to indicate the percentage of completion. When it is complete, the display
will again read “Press
to begin”. Press X to return to the previous menu.
Run this routine after replacing an RF power
module, swapping RF power module
positions, or replacing the controller
Audio input
calibration options
Summary of Contents for GV5
Page 2: ......
Page 4: ......
Page 8: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 2 2014 07 23...
Page 16: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 8 VERSION 0 2 2014 07 23...
Page 18: ...VERSION 0 2 2014 07 23 PAGE 3 1 10 LJXUH 9 9 XGLR 3DWK ORFN LDJUDP...
Page 239: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL ROUTINE MAINTENANCE PAGE 3 3 10 VERSION 0 2 2014 07 23...
Page 249: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 2 2014 07 23...
Page 250: ......