GV20/GV15 INSTALLATION MANUAL
COMMISSIONING
PAGE 2.9.4
VERSION 5.0 2021-03-01
Going On-Air
IMPORTANT!
Before going on the air, if you want the safety interlocks to operate properly, the
shorting jumpers installed in
“Pre-Commissioning Tasks” on page 2.9.2
should be removed.
1.
Turn off the power using the ac disconnect switch, if one is being used, or else at the ac source.
2.
Connect the transmitter's RF output to an antenna system (or verify that the current connection is
intact).
3.
Turn on the transmitter’s ac power.
4.
Verify audio input levels using the AUI.
5.
Use the local AUI to begin transmitter operations. For detailed instructions, refer to the GV20/GV15
Operating and Maintenance Manual.
Set for desired power level.
Press the
RF On
touch screen button.
Select the desired exciter as main, if applicable.
WARNING! If a jumper is placed between the INTLK inputs [TB1-1 and 2 on
the remote interface PWB (A16) or pins 19 and 20 of the controller’s (A4)
REMOTE I/O-A connector (A2J5A)], safety features controlled by the
external interlocks will be disabled. A fail-safe method of alerting
personnel to this fact should be implemented. Voltages which are
dangerous to life will be present on the RF output stages and the antenna
system if the transmitter is turned on.
Summary of Contents for GV20
Page 2: ......
Page 4: ......
Page 8: ...GV20 GV15 INSTALLATION MANUAL PAGE 2 VIII VERSION 5 0 2021 03 01...
Page 18: ...GV20 GV15 INSTALLATION MANUAL UNPACKING AND POSITIONING PAGE 2 2 8 VERSION 5 0 2021 03 01...
Page 24: ...GV20 GV15 INSTALLATION MANUAL INSTALLING OPTIONS PAGE 2 3 6 VERSION 5 0 2021 03 01...
Page 36: ...GV20 GV15 INSTALLATION MANUAL INSTALLING PROGRAM INPUTS PAGE 2 7 4 VERSION 5 0 2021 03 01...
Page 50: ...GV20 GV15 INSTALLATION MANUAL COMMISSIONING PAGE 2 9 8 VERSION 5 0 2021 03 01...
Page 54: ...GV20 GV15 INSTALLATION MANUAL PARTS AND TOOLS PAGE 2 10 4 VERSION 5 0 2021 03 01...
Page 64: ...GV20 GV15 INSTALLATION MANUAL LIST OF TERMS PAGE 2 12 2 VERSION 5 0 2021 03 01...
Page 65: ......