![Nautel GV10 Installation Manual Download Page 35](http://html2.mh-extra.com/html/nautel/gv10/gv10_installation-manual_3505895035.webp)
GV10/GV7.5 INSTALLATION MANUAL
INSTALLING CONTROL/MONITOR WIRING
VERSION 3.0 2014-11-01
PAGE 2.8.3
7.
Connect the appropriate control/monitor cable(s) to the connector(s) described in Section 1.8 of
the GV10/GV7.5 Pre-installation Manual.
For connection to the remote interface PWB (A16), route the control/monitor cables to the top
edge of the remote interface PWB. Strip a small amount of wire from the end of each wire and
connect the control/monitor cables to the appropriate terminals of the
CUSTOMER ALARM/
STATUS
(TB2) and
CUSTOMER CONTROL
(TB3) terminal blocks.
For connection to the controller (A4), route the control/monitor cables to the rear of the
controller. The transmitter’s ancillary kit contains male (Nautel Part # JS31) and female (Nautel
Part # JS28) 25-pin D-sub connectors and connector shells (Nautel Part # JS35) to facilitate
connections to the
REMOTE I/O-A (A1J2A)
and
REMOTE I/O-B (A1J2B)
25-pin D-sub
connectors.
8.
For the transmitter’s external interlock control, route a shielded cable to one of the following
locations:
For connection to the remote interface PWB (A16), connect the shielded cable to TB1,
between
INTLK
terminals 1 and 2 (see
Figure 2.8.2 on page 2.8.4
) or between terminals 19
and 20 on the CUSTOMER CONTROL terminal block (TB3). Use one option only; do not use
both.
IFor connection to the controller (A4),connect the shielded cable to pins 19 and 20 on the
REMOTE I/O-A 25-pin male D-sub connector (A1J2A) on the rear panel of the controller.
9.
For web based control of the transmitter, route an Ethernet (shielded Cat5) cable to one of the
following locations:
For connection to the remote interface PWB (A16), route the Ethernet cable to the right-hand
edge of the remote interface PWB. Connect the Ethernet cable to the
LAN
connector (J1) (see
Figure 2.8.2 on page 2.8.4
).
For connection to the controller (A4), route the Ethernet cable to the rear panel of the
controller. Connect the Ethernet cable to the
LAN (A1J8A)
connector (see
Figure 2.8.3 on page
2.8.5
).
10. Re-install the rear filter panel, removed in Section 2.2, using its 14 1/4-turn latches (see
Figure 2.2.1 on page 2.2.3
).
Summary of Contents for GV10
Page 2: ......
Page 4: ......
Page 8: ...GV10 GV7 5 INSTALLATION MANUAL PAGE 2 VIII VERSION 3 0 2014 11 01...
Page 32: ...GV10 GV7 5 INSTALLATION MANUAL INSTALLING PROGRAM INPUTS PAGE 2 7 4 VERSION 3 0 2014 11 01...
Page 48: ...GV10 GV7 5 INSTALLATION MANUAL PARTS AND TOOLS PAGE 2 10 4 VERSION 3 0 2014 11 01...
Page 60: ...GV10 GV7 5 INSTALLATION MANUAL LIST OF TERMS PAGE 2 12 2 VERSION 3 0 2014 11 01...
Page 61: ......