GV10/GV7.5 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
VERSION 3.2 2016-03-10
PAGE 4.1.53
Remote Interface PWB Replacement
Using
as a guide, replace the remote interface PWB as follows:
Figure 4.1.17: Remote Interface PWB Location
1.
Turn off and lock out the transmitter’s main ac power.
2.
Open the front door to gain access to the remote interface PWB.
3.
Remove all customer interface wiring from the remote interface PWB. Note the destination of each
wire for ease of reconnecting.
4.
Disconnect the two D-sub connectors (W20P2 and W21P2) from the bottom of the PWB and the
Cat5E connector (W29P2) from the right-hand side of the PWB (mates with J2).
Front door open and cabinet
side removed for clarity
Remote
Interface PWB
D-sub connectors
W20P2 and W21P2