GV10/GV7.5 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
PAGE 4.1.2
VERSION 3.2 2016-03-10
Remote Troubleshooting
Remote on-air troubleshooting consists of monitoring the transmitter's radiated signal using an on-air
monitor or via a LAN connection, and observing the status of each remote fault alarm indicator.
Information obtained from these sources should enable an operator to decide whether an alarm
response may be deferred to a more convenient time, an immediate corrective action must be taken, or
if a standby transmitter must be enabled (if one is available). It is recommended that the significance of
remote indications, and the appropriate responses, be incorporated into a station's standard operating
procedures. Refer to
“Identifying an Alarm” on page 4.1.4
to determine the remedial action required for
a given fault.
Local Troubleshooting
Local on-air troubleshooting consists of monitoring the transmitter's integral meters and fault alarm
indicators. Analysis of this data will normally identify the type of fault, and in most cases will determine
what corrective action must be taken. Refer to
“Identifying an Alarm” on page 4.1.4
remedial action required for a given fault.
The power amplifier stage contains an integral modular reserve (IMR) feature. This feature permits the
transmitter to operate at a reduced RF output level when a malfunction occurs in one of its power
modules. Station operating procedures will dictate whether a reduced RF output level is acceptable.
When a reduced RF output level can be tolerated, replacement of the defective RF power module may
be deferred to a convenient time.
A defective RF power module may be removed from the transmitter for servicing, while the transmitter
is operating, provided that the conditions in the removal instructions detailed in
are met.
Off-Air Troubleshooting
Off-air troubleshooting must be performed when the replacement of a defective RF power amplifier
module, or routine on-air calibration adjustments, will not restore operation.
It is recommended that the transmitter’s output be connected to a precision 50
resistive dummy load
(rated for at least the maximum transmitter power rating) before starting off-air troubleshooting
procedures. If an appropriate dummy load is not available, troubleshooting for a majority of faults can
be performed with RF power stage turned off. The transmitter may remain connected to its antenna
system for these procedures.
NOTE
: Reduce the RF output level to a minimal value when troubleshooting faults in the power
amplifier stage while the transmitter’s RF output is connected to the antenna system.
Summary of Contents for GV10
Page 2: ......
Page 4: ......
Page 8: ...GV10 GV7 5 TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 3 2 2016 03 10...
Page 84: ...GV10 GV7 5 TROUBLESHOOTING MANUAL RESPONDING TO ALARMS PAGE 4 1 76 VERSION 3 2 2016 03 10...
Page 236: ......
Page 292: ...VERSION 3 2 2016 03 10 SD 36 Figure SD 36 NAFP109B Output Power Probe and Sample PWBs...
Page 296: ...VERSION 3 2 2016 03 10 SD 40...
Page 300: ...GV10 GV7 5 TROUBLESHOOTING MANUAL MECHANICAL DRAWINGS PAGE 4 5 4 VERSION 3 2 2016 03 10...
Page 313: ...VERSION 3 2 2016 03 10 MD 13 Figure MD 13 NAPA31C Power Amplifier PWB Q1...
Page 324: ...GV10 GV7 5 TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 3 2 2016 03 10...
Page 325: ......