GV10/GV7.5 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
VERSION 3.2 2016-03-10
PAGE 4.1.27
Module #: PS A (or B)
Fail
Power Supply (red)
This alarm occurs if one of the two module power supplies (1 or 2) is
reporting a PS failure, indicating its output voltage is outside its acceptable
range, based on the control setting. Check the dc voltage output of the
suspect power supply module. If the dc voltage is out of tolerance, replace
the power supply module (see
). If the voltage is acceptable, suspect
the PS interface PWB (A1).
Module #: PS A (or B)
High Temperature [PS
A (or B) Temp]
Power Supply (red)
This alarm occurs if one of the two module power supplies (1 or 2) is
reporting a high temperature alarm, indicating its operating temperature
has exceeded its internal threshold of 105°C (221°F). Both module power
supplies are inhibited while this fault exists. This alarm is most likely caused
by a module fan failure or blockage. Verify the module turns on and its fan
is operational. If the fan is not operational, inspect it for possible blockage.
If necessary, replace the power supply module (see
Module Replacement” on page 4.1.50
). If the alarm persist after
replacing the module, suspect the PS interface PWB (A1).
Module #: PS A (or B)
Low Line
Power Supply (red)
This alarm occurs if one of the two module power supplies (1 or 2) is
reporting a low ac input voltage (less than 175 V ac, higher than 90 V ac).
The power supply will limit its associated module’s output.
Module #: PS A (or B)
Missing
Power Supply (red)
This alarm occurs if the module power supply (A or B) is removed, or has not
been detected on the serial bus. Install an operational power supply
module. The alarm may persist for several seconds after replacing a power
supply module, before the power supply module is recognized. If the alarm
persists after one minute, try reseating the power supply module. This alarm
may also be caused by an ac power loss to the power supply module.
Module #: Reject
Power Shutback (Rej
Shutback)
Output Network
(amber)
This alarm occurs when the reject power in the power module’s combiner
suddenly exceeds 600 W, requiring a shutback. This may be the result of a
PA failure or, under certain conditions, may indicate a fault in the
transmitter’s RF combiner/filter. The module will be latched off until a reset
is initiated.
Module #: RF Drive
Loss (RF Drv Loss)
Power Amplifier (red) This alarm occurs if the input RF drive (exciter power) is less than 1 W when
it is expected to be 2 W or higher, based on the measurements from the
remaining power modules. Check the RF drive cable between the splitter
and the module control/interface PWB (A3).
Module #: Switch
Inhibit (Switch Inh)
Power Amplifier (red) This alarm occurs if the module’s front panel switch is in the ‘DISABLE
(down)’ position. Set the switch to its ‘ENABLE (up)’ position to enable the
module.
Device and
Alarm Name
(AUI, UI)
Controller Front
Panel LED (color)
Description and Troubleshooting Action
Summary of Contents for GV10
Page 2: ......
Page 4: ......
Page 8: ...GV10 GV7 5 TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 3 2 2016 03 10...
Page 84: ...GV10 GV7 5 TROUBLESHOOTING MANUAL RESPONDING TO ALARMS PAGE 4 1 76 VERSION 3 2 2016 03 10...
Page 236: ......
Page 292: ...VERSION 3 2 2016 03 10 SD 36 Figure SD 36 NAFP109B Output Power Probe and Sample PWBs...
Page 296: ...VERSION 3 2 2016 03 10 SD 40...
Page 300: ...GV10 GV7 5 TROUBLESHOOTING MANUAL MECHANICAL DRAWINGS PAGE 4 5 4 VERSION 3 2 2016 03 10...
Page 313: ...VERSION 3 2 2016 03 10 MD 13 Figure MD 13 NAPA31C Power Amplifier PWB Q1...
Page 324: ...GV10 GV7 5 TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 3 2 2016 03 10...
Page 325: ......