background image

Product

Manufacturer:

Natus Medical

Incorporated

5900 First Avenue

South

Seattle, WA 98108

USA

Global sales & support: 1-800-303-0306
Phone: 
Fax: 
Web:

+1-206-767-3500
+1-206-762-4200

www.natus.com

The information in this manual is subject to change without notice.

No part of this manual may be photocopied, reproduced, translated, or reduced to any 
electronic medium without the express written permission of Natus Medical Incorporated.

All tradenames and trademarks mentioned herein are property of their respective owners. 
Copyright © 2013 Natus Medical Incorporated. All rights reserved.

Summary of Contents for OLYMPIC BILI-METER 22

Page 1: ...nnecting the Sensor 4 Taking Measurements 5 Cleaning 7 Maintenance and Service 7 Replacing the Battery 7 Calibrating the Bili Meter 8 Service and Repair 8 Returning for Calibration or Service 8 Contac...

Page 2: ...The information in this manual is subject to change without notice No part of this manual may be photocopied reproduced translated or reduced to any electronic medium without the express written perm...

Page 3: ...its packaging Table 2 Symbols OLYMPIC BILI METER Instruction Manual 1 Symbol Definition Shipping Storage Temperature Manufacturer Symbol Definition Atmospheric pressure Battery Caution Humidity conde...

Page 4: ...22 readout Sensor cable connection Display ON READ button Shown with Type B 22 sensor Type B 22 Sensor This sensor is used to measure the irradiance of phototherapy lights placed over the patient e g...

Page 5: ...are centimeter per nanometer W cm2 nm A nanometer is a measure of wavelength equal to one billionth of a centimeter The term per nanometer indicates the average irradiance per nanometer across the spe...

Page 6: ...ert the connector into the socket Figure 5 Connecting the sensor to the readout Socket Readout Connector Figure 6 Disconnecting the sensor Pull Readout Connector sleeve 4 OLYMPIC BILI METER Instructio...

Page 7: ...taken Figure 7 Measuring with the Type B 22 sensor Phototherapy light Sensor aimed for maximum reading 3 Press and hold READ On briefly displays then the irradiance measurement displays While pressing...

Page 8: ...Messages The following messages may show on the display of the readout Table 8 1 Messages 6 OLYMPIC BILI METER Instruction Manual Display Message Description Low Bat Battery power is low replace the...

Page 9: ...he back cover of the readout see Figure 9 An instruction label on the inside of the back cover illustrates how to remove and insert the battery NOTE Figure 9 Replacing the battery Back cover Screws x4...

Page 10: ...ts and must be returned to Natus Medical for all repairs and parts replacement After any service the Bili Meter must be recalibrated radiometrically to assure accurate measurement of irradiance Return...

Page 11: ...sor 53822 Bili Meter Model 22 with Type F 22 sensor 53825 Type B 22 sensor only 53860 Type F 22 sensor only 53865 Note The Type B 22 and Type F 22 sensors can be used interchangeably with the Bili Met...

Page 12: ...ields greater than or equal to 1 V m or contact electrostatic discharge abnormal operation eg display fluctuation or lock up may occur If so re orient the meter and or allow it to auto reset and retak...