1.  When the high-pressure switch determines that the water pressure in-

side the tank is lower than the pre-set value, the system starts operat-
ing. 

2.  The two last digits show the actual TDS value. The TDS value upper 

limit is 100 ppm. If the value exceeds 100 ppm, the symbols 

“100” and 

“TDS” flash one after another. 

3.  If the TDS value is higher than 50 and if the buzzer mode (

“E”) is acti-

vated, a buzzer sounds. 

4. 

The  first  digit  shows  “E”  for  the  buzzer  mode  and  “P”  for  the  mute 
mode, the last of 

which can be activated by pressing the “MUTE” but-

ton. 

5.  Both the probe and the control unit regulate possible deviations in the 

measuring range; do 

not

 combine the system with other devices. 

6.  The TDS measurement can easily be perturbed. Ensure that the probe 

has been introduced to as sufficient depth inside the pipe to guarantee 
accurate measuring results. 

7.  The presence of air bubbles inside the tubing system can influence on 

the accuracy of the TDS measurement. Purge the pipes before using 
the system. (The high-pressure pump works, the inlet valve opens, the 
outlet valve closes.) 

 

1.  The system is activated and is rinsed for 30 s. 
2.  Cumulative  water  production  for  6 h;  do  not  rinse  the  system  during 

that time, it will afterwards be rinsed automatically for 30 s. 

3.  Automatic  rinsing  for  30 s  after  the  lack  of  water  programme  having 

been finished. 

4.  The  last  two  digits  show  the  remaining  back-flushing  time,  the  clock 

symbols flushes once per second. 

5. 

The  first  digit  shows  “E”  for  the  buzzer  mode  and  “P”  for  the  mute 
mode, the last of which ca

n be activated by pressing the “MUTE” but-

ton. 

6.  Rinse  the  system  for  5 s  before  the  water  production  and  the  water 

tank filling. (The high-pressure pump works, the inlet valve opens, the 
outlet valve closes.) 

 

1.  When the high-pressure switch determines that the water pressure in-

side the water tank has reached to pre-set value, the water production 
is stopped. 

2.  Shows  the  last  measured  TDS  value  during  the  water  production  or 

rinsing. When the system does not produce any water, there is no TDS 

Summary of Contents for NW-RO50-D1

Page 1: ...ration similar may vary depending on model Read and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illu...

Page 2: ...ontact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wild...

Page 3: ...h are so small that organic contaminants pesti cides insecticides medicine hormones etc bacteria and viruses are retained The water flowing out of the membrane is stored in a pressure tank When the go...

Page 4: ...ch High pressure switch Granular activated carbon Activated carbon filter Gourmet Block of activated carbon Sixth filter stage if present Booster pump Purified water 4 way valve Flow out from goose ne...

Page 5: ...eck valve L1 Drain valve L2 Drain restrictor M Tank valve N Pressure tank P PI activated carbon filter Gourmet Q Goose neck water tap R Mineral ball UV light 1 2 3 4 Connect plastic hose In this drawi...

Page 6: ...ontent relative to raw water 15 20 Water supply Tap water or ground water TDS 1000 ppm less Installation The system installation method should be determined in accordance with the layout of your kitch...

Page 7: ...ing to the outlet of drain restrictor and flush valve Connect the drain tubing to sewer or connect with a container where you can collect water which can be used for washing or for the toilet Mark 3 b...

Page 8: ...ill flush for 30 s After 2 h of cleaning the water it flushes again for 30 s After 5 s the system responds to the low pressure switch If the high pressure switch operates the system stops after 20 s I...

Page 9: ...ent of the system working for an unusually long time it is automatically switched off in which case a warning buzzer is activated the display being as 5 If you press the button 6 for strong flushing S...

Page 10: ...ing as 5 Once the pressure tank is full the system stops the display being as 2 A buzzer indicates if feed water lacks or the water supply pressure is too low the display being as 3 After two hours of...

Page 11: ...side the tubing system can influence on the accuracy of the TDS measurement Purge the pipes before using the system The high pressure pump works the inlet valve opens the outlet valve closes 1 The sys...

Page 12: ...closes Error message This error message means that the TDS value is higher than 100 ppm The controller setting limit is at 100 ppm precisely If the value is beyond this limit the controller cannot det...

Page 13: ...s during pure water filtering cannot be used as drinking water Re check the system for tightness Operation After the installation and the adjustment the system begins to automatically produce purified...

Page 14: ...ia left on the surface of the membrane which may affect the quality and volume of the purified water Thus the RO membrane must be cleaned periodically In our system the RO membrane is automatically wa...

Page 15: ...ked RO membrane which is caused by a blocked flow restrictor This causes the pump head to be filled with high pressure water that can cause a leak Improve the relevant components No water purifying wi...

Page 16: ...parate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycli...

Reviews: