Commissioning

 

 

After the installation, wash the filters of each stage before using the system for the first time. The steps 
are as follows: turn on the water-tap tubing ball valve

 (B)

, turn off the tank valve

 (M) 

of the water tank

 (N), 

turn on the goose-neck water-tap

 (Q),

 open the flush valve

 (L1).

 Now plug the power cord into the power 

supply socket, and the high-pressure pump

 (H)

 starts up automatically, the dirt water outlet begins to 

drain, filters of each stage are washed automatically. 
 
After having washed the tank, turn on the tank valve

 (M) 

of the water tank

 (N),

 turn off the goose-neck 

water-tap

 (Q),

 turn off the drain valve

 (L1).

 The reverse osmosis filter then begins to purify the water. 

When you use this system for the first time, let the purified water flow out from the full water tank twice, 
then the purified water is suitable for drinking. 
 
The concentrated waste water produces during pure water filtering cannot be used as drinking water. 
Re-check the system for tightness. 
 
 

Operation

 

 
After  the  installation  and  the  adjustment,  the  system  begins  to  automatically  produce  purified  water. 
Usually, turn off the goose-neck water-tap

 (Q),

 turn on the tank valve

 (M) 

of water storage tank, let the 

purified water flow into the tank. When the water storage tank is full of purified water, the system auto-
matically stops. Turn on the goose-neck water-tap

 (Q) 

to use the purified water. If using the system for 

the first time, let the water twice flow out of the tank; it is after that that the purified water can be drunk. 
 

 Notes: 

A)  When you use the system for the first time, turn on the goose-neck water-tap to drain the water 

(black water flowing out from water-tap caused by activated carbon filter). 

B)  When you use the system for the first time, TDS test data may be a bit high; continue washing 

until the TDS test data normalizes. 

C)  When you use the system for the first time, the purified water is not drinkable until steps A and 

B are done. The concentrated dirt water used for the water purifying process cannot be used 
for drinking. 

 

 

Summary of Contents for NW-RO50-D1

Page 1: ...ration similar may vary depending on model Read and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illu...

Page 2: ...ontact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wild...

Page 3: ...h are so small that organic contaminants pesti cides insecticides medicine hormones etc bacteria and viruses are retained The water flowing out of the membrane is stored in a pressure tank When the go...

Page 4: ...ch High pressure switch Granular activated carbon Activated carbon filter Gourmet Block of activated carbon Sixth filter stage if present Booster pump Purified water 4 way valve Flow out from goose ne...

Page 5: ...eck valve L1 Drain valve L2 Drain restrictor M Tank valve N Pressure tank P PI activated carbon filter Gourmet Q Goose neck water tap R Mineral ball UV light 1 2 3 4 Connect plastic hose In this drawi...

Page 6: ...ontent relative to raw water 15 20 Water supply Tap water or ground water TDS 1000 ppm less Installation The system installation method should be determined in accordance with the layout of your kitch...

Page 7: ...ing to the outlet of drain restrictor and flush valve Connect the drain tubing to sewer or connect with a container where you can collect water which can be used for washing or for the toilet Mark 3 b...

Page 8: ...ill flush for 30 s After 2 h of cleaning the water it flushes again for 30 s After 5 s the system responds to the low pressure switch If the high pressure switch operates the system stops after 20 s I...

Page 9: ...ent of the system working for an unusually long time it is automatically switched off in which case a warning buzzer is activated the display being as 5 If you press the button 6 for strong flushing S...

Page 10: ...ing as 5 Once the pressure tank is full the system stops the display being as 2 A buzzer indicates if feed water lacks or the water supply pressure is too low the display being as 3 After two hours of...

Page 11: ...side the tubing system can influence on the accuracy of the TDS measurement Purge the pipes before using the system The high pressure pump works the inlet valve opens the outlet valve closes 1 The sys...

Page 12: ...closes Error message This error message means that the TDS value is higher than 100 ppm The controller setting limit is at 100 ppm precisely If the value is beyond this limit the controller cannot det...

Page 13: ...s during pure water filtering cannot be used as drinking water Re check the system for tightness Operation After the installation and the adjustment the system begins to automatically produce purified...

Page 14: ...ia left on the surface of the membrane which may affect the quality and volume of the purified water Thus the RO membrane must be cleaned periodically In our system the RO membrane is automatically wa...

Page 15: ...ked RO membrane which is caused by a blocked flow restrictor This causes the pump head to be filled with high pressure water that can cause a leak Improve the relevant components No water purifying wi...

Page 16: ...parate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycli...

Reviews: