background image

 

https://www.naturewater.eu 

 

Item 63920, 63921

 

Page 3 

 

 

  

 

11 2023-1

 

 

Introduction

 

 

Thank you for choosing to purchase this quality product. To minimise the risk of injury, we ask you to 
always take some basic safety precautions when using this product. Please read this operating manual 
carefully and make sure that you understand it.

 

Keep these operation instructions in a safe place.

 

 
 

Use and warning notices

 

 

 

Prohibition symbol

 

Any use described with this symbol is prohibited, as otherwise the prod-
uct could be damaged, the safety of users could be jeopardised, or ma-
terial damage could be caused.

 

 

Warning symbol

 

Any use described with this symbol must be carried out in strict compli-
ance with the regulations, otherwise the product could be damaged or 
the safety of the user could be jeopardised.

 

 

Instruction symbol

 

All instructions marked with this symbol must be observed by the user, 
otherwise  the  product  may  be  damaged  or  other  damage  may  occur 
due to improper operation.

 

 

 

Installation, commissioning, or maintenance of this water treatment device must be carried out 
by qualified personnel.

 

 

Liability for consequences caused by improper installation is excluded.

 

 
 

Safety instructions

 

 

 

The water treatment device can only be supplied with 12

 

V and 1500 mA. Observe all safety 

precautions  in  connection  with  the  operation  of  electrical  appliances  during  operation  and 
maintenance.

 

 

If the mains cable of the water treatment device is damaged, it must be repaired by a qualified 
electrician.

 

 

The water treatment device is only suitable for filtering pre-treated tap water. It cannot be used 
to filter water with an unknown level of contamination or an unknown proportion of harmful or-
ganisms.

 

 

The water treatment liquid cannot be drunk directly. Do not drink it directly.

 

 

Do not block the overflow pipe and the drain pipe of the water treatment device.

 

 

Do not place any objects on the water treatment device.

 

 

Do not immerse the water treatment device in water.

 

 

Do not use the water treatment device outdoors or in direct sunlight.

 

 

The temperature of the water entering the treatment device must not exceed 38

.

 

 

After the water treatment device has been shut off for more than a week, the water must be 
drained during 5

 

min before water coming from the device can be used for food purposes.

 

 

The power supply must not be interrupted while the water treatment device is in use in order to 
avoid timing errors, which would affect the originally set backwash start time.

 

 

As hot water can severely damage the internal treatment system, it should be ensured that there 
is a connecting pipe of at least 3

 

m in length between the outlet of the treatment device and the 

inlet of the hot water boiler. If the 3-m connection line cannot be assured, it is recommended to 
install a non-return valve between the water treatment device and the hot water boiler.

 

Summary of Contents for 63920

Page 1: ...perating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous furth...

Page 2: ...u have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recen...

Page 3: ...f electrical appliances during operation and maintenance If the mains cable of the water treatment device is damaged it must be repaired by a qualified electrician The water treatment device is only s...

Page 4: ...water must be avoided e g by quickly opening or closing the valve and switching off the water pump in emergencies Do not apply force to the machine and avoid direct sunlight and exposure to heat from...

Page 5: ...https www naturewater eu Item 63920 63921 Page 5 11 2023 1 Overview Name Name 1 Inlet outlet 6 Cover 2 Relief valve 7 Belt 3 Display 8 Housing 4 Control panel 9 FRP tank 5 Cover plate 10 Central pipe...

Page 6: ...re captured at the same time the coconut shell activated carbon filters chlorine organic substances turbidity odours etc out of the water Backwashing Backwashing with tap water from bottom to top thro...

Page 7: ...s station open the tap in the house and drain the water from the dirty water supply station The water treatment device must not be tilted or laid on its side during transport installation or use The f...

Page 8: ...from the treatment device or pipework due to stresses in the pipework during long term use It is forbidden to combine the overflow and drain pipes in one pipe and insert it into the waste water outlet...

Page 9: ...Clamp fixed water pipe 4 Intake 2 Outlet 5 Inlet pipe 3 Outlet pipe 6 Clamp fixed water pipe Note Please note the actual height and installation environment of the selected product 2 Connect the bypas...

Page 10: ...to prevent the hose from jumping out of the waste pipe 4 Return to step 2 Place the product in the corresponding position of the installed connection Connect the water inlet and outlet of the bypass v...

Page 11: ...ase check whether the large insert on the bypass valve is inserted all the way to the bottom Check that the sealing rings on the two bypass pipe connections are correctly installed 5 After completing...

Page 12: ...special circumstances the bypass valve of the machine can be set to the bypass state push the pull rod to the operating position as shown in Fig 2 You can temporarily use the municipal water supply di...

Page 13: ...th a clamp Note This pro cedure is intended to ensure that the hose is not pushed away or pushed out of the sewer if the flat is connected to the sewer or the water pressure of the floor drain is high...

Page 14: ...time the regeneration time the raw water hardness and other parameters can be set The background mode is set by the manu facturer at the factory e g backwash brine and slow rinse refill quick rinse w...

Page 15: ...holding In the parameter settings menu press and hold to change the individual parameter values Press and simultaneously for 5 s to cancel the key lock Description of the parameters Parameter Model Fa...

Page 16: ...is displayed as shown in Fig D When the valve rotates from one operating position to another the menu is displayed as shown in Fig E If there is an error in the system the display appears as shown in...

Page 17: ...perating mode of the control valve This means that different operating modes have different setting menus The description of the setting lines of the unla belled operating modes is displayed in all op...

Page 18: ...ocket 3 Power cut off 3 Re establish power 4 Defective transformer 4 Replace transformer 5 Defective control valve 5 Replace control valve Backwash time incorrect Power failure loose contact of the ma...

Page 19: ...ody of valve replace if necessary 2 Power failure during backwash or quick rinse 2 Set valve to service operating mode or switch off bypass valve and restart as soon as power supply is restored Note T...

Page 20: ...nd other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domes...