Description of the parameters

 

 

Parameter

 

Model

 

Factory 

setting 

(time)

 

Parameter setting 

range (values)

 

Explanations

 

Current time

 

All

 

 

00:00–23:59

 

 

Rinsing time

 

All

 

2:00

 

00:00–23:59

 

 

Operation days

 

All

 

30

 

0–99

 

If the set days have 

elapsed, the backwash 

is started as soon as 

the system time 

matches the set back-

wash time.

 

Backwash time

 

CF-M1-C

 

2

 

0–99

 

Minutes

 

CF-M1

 

2

 

CF-M2

 

3

 

Quick-rinse time

 

CF-M1-C

 

3

 

0–99

 

Minutes

 

CF-M1

 

3

 

CF-M2

 

4

 

 
 

 

Summary of Contents for 63920

Page 1: ...perating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous furth...

Page 2: ...u have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recen...

Page 3: ...f electrical appliances during operation and maintenance If the mains cable of the water treatment device is damaged it must be repaired by a qualified electrician The water treatment device is only s...

Page 4: ...water must be avoided e g by quickly opening or closing the valve and switching off the water pump in emergencies Do not apply force to the machine and avoid direct sunlight and exposure to heat from...

Page 5: ...https www naturewater eu Item 63920 63921 Page 5 11 2023 1 Overview Name Name 1 Inlet outlet 6 Cover 2 Relief valve 7 Belt 3 Display 8 Housing 4 Control panel 9 FRP tank 5 Cover plate 10 Central pipe...

Page 6: ...re captured at the same time the coconut shell activated carbon filters chlorine organic substances turbidity odours etc out of the water Backwashing Backwashing with tap water from bottom to top thro...

Page 7: ...s station open the tap in the house and drain the water from the dirty water supply station The water treatment device must not be tilted or laid on its side during transport installation or use The f...

Page 8: ...from the treatment device or pipework due to stresses in the pipework during long term use It is forbidden to combine the overflow and drain pipes in one pipe and insert it into the waste water outlet...

Page 9: ...Clamp fixed water pipe 4 Intake 2 Outlet 5 Inlet pipe 3 Outlet pipe 6 Clamp fixed water pipe Note Please note the actual height and installation environment of the selected product 2 Connect the bypas...

Page 10: ...to prevent the hose from jumping out of the waste pipe 4 Return to step 2 Place the product in the corresponding position of the installed connection Connect the water inlet and outlet of the bypass v...

Page 11: ...ase check whether the large insert on the bypass valve is inserted all the way to the bottom Check that the sealing rings on the two bypass pipe connections are correctly installed 5 After completing...

Page 12: ...special circumstances the bypass valve of the machine can be set to the bypass state push the pull rod to the operating position as shown in Fig 2 You can temporarily use the municipal water supply di...

Page 13: ...th a clamp Note This pro cedure is intended to ensure that the hose is not pushed away or pushed out of the sewer if the flat is connected to the sewer or the water pressure of the floor drain is high...

Page 14: ...time the regeneration time the raw water hardness and other parameters can be set The background mode is set by the manu facturer at the factory e g backwash brine and slow rinse refill quick rinse w...

Page 15: ...holding In the parameter settings menu press and hold to change the individual parameter values Press and simultaneously for 5 s to cancel the key lock Description of the parameters Parameter Model Fa...

Page 16: ...is displayed as shown in Fig D When the valve rotates from one operating position to another the menu is displayed as shown in Fig E If there is an error in the system the display appears as shown in...

Page 17: ...perating mode of the control valve This means that different operating modes have different setting menus The description of the setting lines of the unla belled operating modes is displayed in all op...

Page 18: ...ocket 3 Power cut off 3 Re establish power 4 Defective transformer 4 Replace transformer 5 Defective control valve 5 Replace control valve Backwash time incorrect Power failure loose contact of the ma...

Page 19: ...ody of valve replace if necessary 2 Power failure during backwash or quick rinse 2 Set valve to service operating mode or switch off bypass valve and restart as soon as power supply is restored Note T...

Page 20: ...nd other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domes...