Page 38
5200 & 5200QL MACHINE MAINTENANCE
SIDE AND REAR PANELS
To Remove A Panel
1.Lift hood and secure in place.
2.Using proper wrench size, remove desired side or rear panel.
OIL LEVEL
To Check Oil Level
1.
Remove Breather Dip Stick (See Figure A)
2.
Check to see that Hydraulic Fluid is visible on Dip Stick
OR
1.Remove Filler plug (See Figure B).
2.Oil should be visual 2” below hole.
3.Reinsert plug.
OIL CHANGE OUT
1. Disconnect machine from power (charger or battery).
2. Drain fluid by removing the drain plug from side of tank (See Figure B).
Take Caution:
this unit
contains twelve gallons of fluid. Make sure you have the proper amount of containers to catch fluid.
3. Replace drain plug.
4. Remove filler plug (See Figure B).
5. Add oil into the filler plug hole until visual 2” below hole.
WHEEL MOTOR CHANGE OUT
1. Disconnect machine from power.
2. Block up machine to remove wheel. See wheel changing on page 40.
3. Remove wheel.
4. Remove oil lines from wheel motor. A small amount of oil will run out of the lines. Drain into a
container. Wipe up spills immediately.
5. Remove four ½" wheel motor securing nuts.
6. Pull out on wheel motor to remove.
Figure A
Figure B
Drain Plug
Filler Plug
Breather
Dip Stick