![National 5200 PANTHER Instruction Manual Download Page 17](http://html1.mh-extra.com/html/national/5200-panther/5200-panther_instruction-manual_3371721017.webp)
Page 13.1a
5200 & 5200QL BATTERY OPERATION
48 VOLT CHARGER INFORMATION
Chargers are fully automatic. The input and output of the charger is microprocessor controlled. The output is current
limited for the protection of your equipment.
! This Safety Alert Symbol Means Attention! Become Alert! Your Safety Is Involved
Machine Charging
Figure A
Figure B
Figure C
Figure D
Charging can be done in or out of the machine. For machine charging
turn the kill switch to the off position (See Figure A). Open and secure
the rear hood (see Figure B) (keep open for ventilation). Unplug the blue
48 volt plug (See Figure C). Power packs must be connected together
(hooked in series, gray plugs on top of the packs). Connect the charger
to the blue 48 volt plug (See Figure D). Connect the charger to a power
source. Connecting to power source starts the charging automatically.
Charging is complete once the LED stays solid green. Disconnect the
charger from the power source. Disconnect the charger from the
machine. Reconnect the blue 48 volt plug to the power pack. Turn kill
switch to the on position.
CHARGING - 48 VOLT CHARGER
READ ALL SAFETY INSTRUCTIONS BEFORE OPERATING THIS UNIT
CAUTION:
This charger is designed ONLY to be used with National’s #5204 Extended Run Power Packs. DO NOT
use this charger with the #5203 lift-out style power packs or any other batteries. Failure to follow this warning may cause
damage to charger, batteries and/or personal injury & will void all warranties.