This section provides recommended test setup procedure for the device evaluation. Figure 2 depicts a 
typical setup and instrumentation you may use for the device evaluation. 

  
1.

 

Apply the power to the device (3.3V typical) between VDD2 and GND connectors. 

 
2.

 

Connect a signal source (i.e. signal generator or an LVDS driver) to the input (R1 label) on the 
board and adjust the signal parameters (VOH, VOL, VCM) so that they comply with the device 
input recommendations. 

 

3.

 

Connect the output (U1 label) to an oscilloscope and view the output signals with an oscilloscope 
that has the bandwidth of at least 3 GHz. 

 

 

 

Figure 2. 

DS10BR150 Test Setup Example

 

 
 
 

  

Page 4 of 5 

Summary of Contents for DS10BR150EVK

Page 1: ...r Repeater DS10BR150 Evaluation Kit USER MANUAL Part Number DS10BR150EVK NOPB For the latest documents concerning these products and evaluation kit visit lvds national com Schematics and gerber files...

Page 2: ...DS10BR150EVK User Manual Table of Contents Table of Contents 2 Overview 3 DS10BR150EVK Description 3 DS10BR150 Evaluation 4 Typical Performance 5 Page 2 of 5...

Page 3: ...gest the test setup procedures and instrumentation and guide you through some typical measurements that demonstrate performance of the device in typical applications DS10BR150EVK Description Figure 1...

Page 4: ...device 3 3V typical between VDD2 and GND connectors 2 Connect a signal source i e signal generator or an LVDS driver to the input R1 label on the board and adjust the signal parameters VOH VOL VCM so...

Page 5: ...User Manual Typical Performance This section of the User Manual shows a typical eye diagram you can expect to see when evaluating the DS10BR150EVK Figure 2 DS10BR150 1 06 Gbps PRBS 7 Output Eye Diagra...

Page 6: ......

Page 7: ...ONN 142 0701 851 EMERSON SMA Jack Receptacle 50 OHM Pb Free 4 0 SMA1 2 5 6 10 11 STENCL T 05801R1 ENERCON STENCIL FABRICATION TOP DS25BR150 DS10BR150 EVK 1 0 12 STENCL T 05802R1 ENERCON STENCIL FABRIC...

Page 8: ...This document is considered uncontrolled unless stamped otherwise Creation Date 2 27 2007 Responsible Eng Mgr Creator Arlene Fox PL Number Z3054 01 Rev 0 Rev Date 2 27 2007 PL Status Released Rev By M...

Reviews: