NI TB-2641 Installation Instructions

2

ni.com

3.

Loosen the two screws on the strain-relief assembly and remove the 
strain-relief bar.

4.

Remove the two screws from the column connection board and retain 
the plastic spacer.

5.

Disconnect the column connection board from the module interface 
board by sliding it toward the front of the terminal block housing. 

6.

Connect each ribbon cable to the appropriate headers on the column 
connection board and the module interface board.

7.

Reassemble the terminal block.

Note

For information about protection resistance and matrix expansion, refer to the 

NI Switches Help

.

Figure 1.  

NI TB-2641 Terminal Block

1

Top Cover Screw

2

Top Cover

3

Strain-relief Screws

4

Strain-relief Bar

5

Column Connection Board Screws

6

Column Connection Board

7

Module Interface Board

8

Column Headers

9

Row Headers

10 Housing

1

2

5

7

9

10

6

4

3

8

Summary of Contents for TB-2641

Page 1: ...ll the terminal block Make sure you have the following NI TB 2641 terminal block 1 8 in flathead and 1 Phillips screwdrivers Eight 2 mm jumpers Two 34 conductor 28 AWG 050 in pitch ribbon cable assemblies not included One 16 conductor 28 AWG 050 in pitch ribbon cable assembly not included Note Refer to the Accessories section for information about ordering the appropriate cable assemblies Connecti...

Page 2: ...he terminal block housing 6 Connect each ribbon cable to the appropriate headers on the column connection board and the module interface board 7 Reassemble the terminal block Note For information about protection resistance and matrix expansion refer to the NI Switches Help Figure 1 NI TB 2641 Terminal Block 1 Top Cover Screw 2 Top Cover 3 Strain relief Screws 4 Strain relief Bar 5 Column Connecti...

Page 3: ...ccessories for the NI TB 2641 Accessory Manufacturer Part Number NI SCB 264X screw terminal block National Instruments 779341 01 Row and column cable kit for the NI SCB 264X terminal blocks National Instruments 779346 01 Row connection cable for column expansion National Instruments 779325 01 16 Conductor 05 in pitch ribbon cable assemblies Samtec FFSD 08 01 N 34 Conductor 05 in pitch ribbon cable...

Page 4: ...eristics All input characteristics are DC ACpk or a combination unless otherwise specified Maximum switching voltage Channel to channel 100 V Channel to ground 100 V CAT I Caution This module is rated for Measurement Category I and intended to carry signal voltages no greater than 100 V This module can withstand up to 500 V impulse voltage Do not use this module for connections to signals or for m...

Reviews: