![background image](http://html1.mh-extra.com/html/national-instruments/scxi-1325/scxi-1325_installation-manual_3506868005.webp)
SCXI-1325 Installation Guide
4
www.ni.com
5.
Connect the wires to the screw terminals by inserting the stripped end
of the wire fully into the terminal. No bare wire should extend past the
screw terminal. Exposed wire increases the risk of shorting and
causing a failure.
6.
Tighten the screws to a torque of 5–7 in.-lb.
7.
Connect safety earth ground to the safety-ground solder lug. Refer to
the
section for connection information.
8.
Reinstall the strain-relief bar and tighten the strain-relief screws.
9.
Reinstall the top cover and tighten the top cover screws.
10. Connect the terminal block to the module front connector as explained
in the
section.
Figure 1 shows the SCXI-1325 terminal block parts locator diagram.
Figure 1.
SCXI-1325 Parts Locator Diagram
1
Strain-Relief Bar
2
Strain-Relief Screws
3
Safety-Ground
Solder Lug
4
Mating Connector
5
Thumbscrew
6
Top Cover Screws
7
Top Cover
2
7
3
6
4
5
1
Back View
Front View
Summary of Contents for SCXI-1325