 National Instruments Corporation

3

SCXI-1305 Installation Guide

This icon denotes a caution, which advises you of precautions to take to 
avoid injury, data loss, or a system crash.

 

When this symbol is marked on a 

product, refer to the 

Read Me First: Safety and Radio-Frequency 

Interference

 for information about precautions to take.

When symbol is marked on a product, it denotes a warning advising you to 
take precautions to avoid electrical shock.

When symbol is marked on a product, it denotes a component that may be 
hot. Touching this component may result in bodily injury.

italic

Italic text denotes variables, emphasis, a cross-reference, or an introduction 
to a key concept. Italic text also denotes text that is a placeholder for a word 
or value that you must supply.

monospace

Text in this font denotes text or characters that you should enter from the 
keyboard, sections of code, programming examples, and syntax examples. 
This font is also used for the proper names of disk drives, paths, directories, 
programs, subprograms, subroutines, device names, functions, operations, 
variables, filenames, and extensions.

Configuring Floating or Ground-Referenced Signals

Before installing and using the terminal block, you must determine what 
type of signal sources are in the SCXI system. Signal sources are either 
floating or ground-referenced.

floating source

 is not connected in any way to the building ground 

system and has an isolated ground-reference point that you cannot assume 
is at the same potential as any other ground. Examples of floating sources 
include transformers, insulated thermocouples, optical isolators, isolation 
amplifiers, and battery-powered devices.

ground-referenced

 source is connected to the building ground and shares 

a common ground with the DAQ device, assuming the computer is 
connected to the building power supply. Examples of ground-referenced 
signals are the nonisolated outputs of any device that plugs into the building 
power supply, such as signal generators and power supplies. Isolated 
outputs do not constitute ground-referenced sources and are treated as 
floating sources.

Reference an input signal to ground at only one point. Do 

not 

reference the 

input of a differential amplifier module to ground if the signal source is 
already ground-referenced. If you are measuring a floating source, 
reference the input to ground.

Summary of Contents for SCXI -1305

Page 1: ...e SMB connector for easy connection The eight BNCs are for signal connections to the eight module inputs The SMB provides access to module digital signals HOLDTRIG for the SCXI 1140 and OUTCLK and EXT...

Page 2: ...Safety and Radio Frequency Interference DAQ Getting Started Guide SCXI Quick Start Guide User manual for the module used SCXI chassis or PXI SCXI combination chassis user manual Technical Support Info...

Page 3: ...bles filenames and extensions Configuring Floating or Ground Referenced Signals Before installing and using the terminal block you must determine what type of signal sources are in the SCXI system Sig...

Page 4: ...ion with the SCXI 1120 D SCXI 1121 SCXI 1125 or SCXI 1126 Use the G position with ground referenced sources Setting the switch to the G position disconnects the resistor from the signal path Always us...

Page 5: ...e capacitors can block up to 50 VDC however voltages applied to the terminal block must not exceed 42 VDC For DC coupling set both switches to the DC position DC coupling removes the filters from the...

Page 6: ...ring and the SCXI module you are using The top set of switches S1 S2 and S3 corresponds to input channel 0 the next set down S4 S5 and S6 corresponds to input channel 1 and so on The bottom set of swi...

Page 7: ...ion Guide Figure 1 SCXI 1305 Parts Locator Diagram 1 Rear Connector 2 Thumbscrew 3 Top Cover Screws 4 Top Cover 4 3 1 2 HOLD CLK M A X I N P U T 4 2 V O L T S C H 4 C H 3 C H 2 C H 1 C H 0 C H 7 C H 6...

Page 8: ...es 8 Channel 6 Switches 9 Channel 7 Switches 10 Serial Number 11 AC DC Coupling Switches 12 Floating Ground Reference Switches 13 SCXI 1121 Signal Connections 14 SCXI 1120 D 1125 1126 1140 1141 1142 1...

Page 9: ...5 Circuit Diagram Specifications All specifications are typical at 25 C unless otherwise specified Electrical Compatible modules SCXI 1120 D 8 input channels SCXI 1121 4 input channels 4 excitation ou...

Page 10: ...within 42 VDC of the voltage applied to any other channel Field wiring connectors Signal connectors 8 female BNC connectors Auxiliary connectors 1 female SMB connector Signal connector spacing 1 8 cm...

Page 11: ...CXI 1305 Dimensions Weight 412 gm 14 5 oz Environment Operating temperature 0 to 50 C Storage temperature 20 to 70 C Humidity 10 to 90 RH noncondensing Maximum altitude 2 000 meters Pollution Degree i...

Page 12: ...fer to the Declaration of Conformity DoC for this product for any additional regulatory compliance information To obtain the DoC for this product visit ni com certification search by model number or p...

Page 13: ...cycle all products must be sent to a WEEE recycling center For more information about WEEE recycling centers and National Instruments WEEE initiatives visit ni com environment weee htm RoHS National I...

Page 14: ...Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appr...

Reviews: