RMC-8357 Installation Guide
|
© National Instruments
|
9
Cable Retention Bracket
The RMC-8357 includes a cable retention bracket. Install the bracket with the retaining screws,
as shown in Figure 3.
Figure 3.
Cable Retention Bracket
Connecting Safety Ground
The RMC-8357 is designed with a three-position IEC C14 style plug that connects the ground
line to the chassis ground. To minimize shock hazard, make sure the electrical power outlet you
use to power the chassis has an appropriate earth safety ground.
Note
The RMC-8357 also includes a grounding screw (8-32 thread size nut) on the
back of the chassis. (The nut is not supplied with the RMC-8357.)
Connecting to Power Source
Attach input power through the rear AC/DC inlet using the appropriate AC/DC power cable
supplied.
Caution
Overloading the circuits may damage supply wiring. Do not exceed the
ratings on the equipment nameplate when connecting equipment to the supply circuit.
Caution
To completely remove power, you
must
disconnect the AC/DC power cable.
Caution
For a DC power supply, provide a 30 A or higher overcurrent protection
device external to the equipment.
The power switch allows you to power on the chassis or place it in standby mode. Push the power
switch to the On position (if not already on). Observe that all fans become operational and the
power indicator is lit.
1
Retaining Screw (x2)
2
Cable Retention Bracket
1
2