Code
(hex)
Additional code
Meaning
Remedy
0A02
Current status of the
local bus master
A service was called that is not
permitted in the current status of
the local bus master.
Possible states:
0001 Ready (After restart or
reset)
0002 Load Config
(Configuration cannot be
loaded)
0004 Config Ready
(Configuration loaded
successfully)
0008 Active (Configuration
frame connected)
0010 Param Ready
(Parameterization of modules
completed)
0020 Run (Process data
traffic running)
0080 Force Mode (Startup
tool specifies outputs)
0100 Ready Fail
(Communication abort in
Ready)
0800 Active Fail
(Communication abort in
Active)
1000 Param Ready Fail
(Communication abort in
Ready parameter)
2000 Run Fail (Process data
traffic with subsystem)
4000 Force Fail (Application
timeout for all devices)
8000 Force Mode Fail
(Communication abort in
Force_Mode)
Set the local bus master
to the required state.
14
|
ni.com
|
REM-11180 User Manual