3. Expand your 

Chassis

 tree item.

MAX lists all modules installed in the chassis. Your default names may vary.

Note

 

If you do not see your module listed, press <F5> to refresh the list of

installed modules. If the module is still not listed, power off the system, ensure

the module is correctly installed, and restart.

4. Record the identifier MAX assigns to the hardware. Use this identifier when

programming the PXIe-5763.

5. Self-test the hardware by selecting the item in the configuration tree and clicking 

Self-

Test

 in the MAX toolbar.

The MAX self-test performs a basic verification of hardware resources.

FlexRIO Examples

FlexRIO includes several example applications for LabVIEW. These examples serve as

interactive tools, programming models, and as building blocks in your own applications.

Accessing FlexRIO Examples

FlexRIO examples are available in LabVIEW's NI Example Finder. Complete the following

steps to access the examples by task.
1. In LabVIEW, click 

Help

»

Find Examples

.

2. In the 

NI Example Finder

 window that appears, click 

Hardware Input and Output

»

FlexRIO

.

The examples are sorted by task. Click on an example and refer to the 

Information

window for a description of the example. Refer the 

Requirements

 window for a list of

hardware devices that can run the example.
You can also click the Search tab to search all installed examples by keyword. For

example, search for 

FlexRIO

 to locate all FlexRIO examples.

Examples also are available online that demonstrate FlexRIO basics, such as using DRAM,

acquiring data from adapter modules, and performing high throughput streaming. Refer to 

ni.com/examples

 for these examples and for more information.

Block Diagram

The following figure shows a block diagram of the carrier portion of the PXIe-5763 (KU035

FPGA version).

PXIe-5763 Getting Started Guide

  | 

© National Instruments

  | 

9

Summary of Contents for PXIe-5763

Page 1: ...PXIe 5763...

Page 2: ...t documentation where this symbol is marked Contents Safety Guidelines 2 Electromagnetic Compatibility Guidelines 2 FlexRIO Documentation and Resources 2 Verifying the System Requirements 3 Unpacking...

Page 3: ...as To minimize interference with radio and television reception and prevent unacceptable performance degradation install and use this product in strict accordance with the instructions in the product...

Page 4: ...System Requirements To use the PXIe 5763 your system must meet certain requirements For more information about minimum system requirements recommended system and supported application development envi...

Page 5: ...F Class 3 low temperature limit and MIL PRF 28800F Class 4 high temperature limit Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Maximum altitude 2 000 m 800 m...

Page 6: ...ng Start All Programs National Instruments NI FlexRIO Installing the PXIe 5763 Caution To prevent damage to the PXIe 5763 caused by ESD or contamination handle the module using the edges or the metal...

Page 7: ...ule in place by pulling up on the ejector handle 10 Secure the module front panel to the chassis using the front panel mounting screws Note Tightening the top and bottom mounting screws increases mech...

Page 8: ...t Panel PXIe 5763 FlexRIO Digitizer DIO 16 Bit 500 MS s 4 Vpp MAX AI 0 AI 1 AI 2 AI 3 REF CLK IN The following table describes the signal connections for the PXIe 5763 PXIe 5763 Getting Started Guide...

Page 9: ...powered on To avoid permanent damage to the PXIe 5763 do not apply a signal to the device when the module is powered down Notice Connections that exceed any of the maximum ratings of any connector on...

Page 10: ...ples FlexRIO examples are available in LabVIEW s NI Example Finder Complete the following steps to access the examples by task 1 In LabVIEW click Help Find Examples 2 In the NI Example Finder window t...

Page 11: ...m of the carrier portion of the PXIe 5763 KU040 and KU060 FPGA versions Figure 5 Carrier Block Diagram KU040 and KU060 DIO Connector Front Panel Adapter Module Connector 5 V 1 8 V 12 V GPIO Configurat...

Page 12: ...tual Property CLIP The LabVIEW FPGA Module includes component level intellectual property CLIP for HDL IP integration FlexRIO devices support two types of CLIP user defined and socketed User defined C...

Page 13: ...hooting procedure contact NI technical support or visit ni com support What Should I Do if the PXIe 5763 Doesn t Appear in MAX 1 In the MAX configuration tree expand Devices and Interfaces 2 Expand th...

Page 14: ...specifications more about your products through ni com the application development environment ADE for your application This item is also installed with the driver software Support ni com support Loca...

Page 15: ...ovide up to date contact information support phone numbers email addresses and current events Information is subject to change without notice Refer to the NI Trademarks and Logo Guidelines at ni com t...

Reviews: