signal connected to CH2 is routed to COM0
2-Wire 64×1 Multiplexer Topology
+
–
com0
+
–
ch0
+
–
ch1
+
–
ch63
Both the scanning command, ch2->com0;, and the immediate operation, niSwitch
Connect Channels VI or the niSwitch_Connect function with parameters ch2 and
com0, result in the following connection:
■
signal connected to CH2+ is routed to COM0+
■
signal connected to CH2- is routed to COM0-
2-Wire Dual 32×1 Multiplexer Topology
ni.com
8
PXI-2530 Features