signal connected to CH2 is routed to COM0
1-Wire Octal 16×1 Multiplexer Topology
ch0
ch1
ch15
com0
ch16
ch17
ch31
com1
ch32
ch33
ch47
com2
ch48
ch49
ch63
com3
ch79
com4
ch95
com5
ch111
com6
ch127
com7
ch64
ch65
ch80
ch81
ch96
ch97
ch112
ch113
Both the scanning command, ch2->com0;, and the immediate operation, niSwitch
Connect Channels VI or the niSwitch_Connect function with parameters ch2 and
com0, result in the following connection:
© National Instruments
7
PXI-2530 Features