Getting Started with the NI EVS-1464RT

2

ni.com

installations, CAT 5 cables are likely to cause increased bit errors resulting in degraded or unreliable 
network performance.

One of the following types of cameras:

IEEE 1394 camera

1

GigE Vision camera

One of the following cables, corresponding to your camera type:

9-pin IEEE 1394 cable for connecting to IEEE 1394b cameras

1

CAT 5e or CAT 6 1000Base-T Ethernet cable for connecting to GigE Vision cameras

Required Software

Use one of the following application development environments to develop NI EVS-1464RT 
applications:

LabVIEW 8.6 or later and the following add-on modules:

LabVIEW Real-Time Module 8.6 or later

NI Vision Development Module 8.6 or later

NI Vision Acquisition Software 8.6.1 or later (included with the NI EVS-1464RT)

NI Vision Builder for Automated Inspection 3.6.1 or later

Optional Equipment

National Instruments offers a variety of products for use with the NI EVS-1464RT, including the 
following:

NI Vision I/O Terminal Block and Prototyping Accessory (part number 779166-01)

2

Digital I/O cable and horizontal DIN rail terminal block (part number 778790-01)

2

Digital I/O cable and vertical DIN rail terminal block (part number 778791-01)

2

Visit 

ni.com

 or call the National Instruments office nearest you for more specific information about 

these products.

Safety Information

The following section contains important safety information that you must follow when installing and 
using the hardware.

Do not operate the hardware in a manner not specified in this document and in the user documentation. 
Misuse of the hardware can result in a hazard. You can compromise the safety protection if the hardware 
is damaged in any way. If the hardware is damaged, return it to National Instruments for repair.

Clean the hardware with a soft, nonmetallic brush. Make sure that the hardware is completely dry and 
free from contaminants before returning it to service.

Do not substitute parts or modify the hardware except as described in this document. Use the hardware 
only with the chassis, modules, accessories, and cables specified in the installation instructions or 
specifications. You must have all covers and filler panels installed during operation of the hardware.

1   

To connect an IEEE 1394a camera to the NI EVS-1464RT, you will need a 6-pin to 9-pin cable or a 6-pin to 9-pin adapter.

2   

When using this accessory with the NI EVS-1464RT, three of the digital I/O signals on the device are not accessible. Refer to 

the 

General-Purpose Digital I/O 

section of Chapter 2, 

LED Indicators, DIP Switches, and Connectors

, in the 

NI EVS-1464 

Series User Manual

 for more information.

Summary of Contents for NI EVS-1464RT

Page 1: ...1464RT kit the following components are necessary to set up and configure the NI EVS 1464RT One of the following power supply options Caution Use the NI EVS 1464RT only with a 24 VDC UL listed limite...

Page 2: ...t ni com or call the National Instruments office nearest you for more specific information about these products Safety Information The following section contains important safety information that you...

Page 3: ...ses overvoltage from the circuit to which they are connected during measurement or test Measurement categories establish standard impulse withstand voltage levels that commonly occur in electrical dis...

Page 4: ...radio communications services or other nearby electronics which can be determined by turning the hardware off and on you are encouraged to try to correct the interference by one or more of the follow...

Page 5: ...in or unplugging any connector Ground the unit to minimize the possibility of static electricity damage Refer to Figure 1 while completing the following steps to install the NI EVS 1464RT Figure 1 NI...

Page 6: ...ion Cameras Connect the camera Ethernet cable to the secondary network connector on the NI EVS 1464RT front panel The camera is now attached to the NI EVS 1464RT Connecting the Power Supply To connect...

Page 7: ...power supply cord into an outlet The orange ISO LED on the NI EVS 1464RT front panel will illuminate when the computer is on and an isolated power supply is properly connected Configuring the Developm...

Page 8: ...T To use MAX to configure the NI EVS 1464RT complete the instructions in the Configuring the NI EVS 1464RT with MAX section of this document Installing NI Vision Acquisition Software The latest versio...

Page 9: ...4RT The NI EVS 1464RT automatically attempts to detect the presence of a network If a DHCP server is not available the NI EVS 1464RT uses a link local address to connect directly to the development co...

Page 10: ...ied to it The NI EVS 1464RT is now connected to the development computer through a network Configuring the NI EVS 1464RT for Deployment The following sections describe how to use the application devel...

Page 11: ...t the NI EVS 1464RT with a MAC address that corresponds to the MAC address on the bottom label of the NI EVS 1464RT you want to configure Refer to Appendix D Common Questions of the NI EVS 1464 Series...

Page 12: ...Vision Builder AI RT Images directory where Vision Builder AI is the location where Vision Builder AI is installed 4 Click OK to apply the IP configuration settings and download software to the NI EVS...

Page 13: ...l Programs National Instruments Measurement Automation 2 Expand the Remote Systems branch of the configuration tree and select the device you want to configure Refer to Appendix D Common Questions of...

Page 14: ...ttings to open the Advanced Ethernet Settings dialog box 4 Select the MAC address for the secondary Ethernet connector from the Ethernet Devices list 5 Select TCP IP Network in the Mode list 6 Manuall...

Page 15: ...464RT systems are intended for indoor use only Maximum altitude 2 000 m Pollution Degree IEC 60664 2 Operating Environment Ambient temperature range 0 C to 45 C IEC 60068 2 1 and IEC 60068 2 2 Relativ...

Page 16: ...ctive safety 2004 108 EC Electromagnetic Compatibility Directive EMC Online Product Certification Refer to the product Declaration of Conformity DoC for additional regulatory compliance information To...

Page 17: ...I Documentation You can also access context help within Vision Builder AI by clicking the Show Context Help button on the Vision Builder AI toolbar Examples of common Vision Builder AI inspections are...

Page 18: ...calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also...

Page 19: ...ther product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate locat...

Reviews: