Getting Started with the NI EVS-1464RT
Deploying Multiple NI EVS-1464RT Devices
As with all Ethernet devices, you can connect multiple NI EVS-1464RT devices to the same network.
This feature allows remote configuration, programming, and monitoring of any NI EVS-1464RT device
not protected by a firewall or user password.
Use the serial number and media access control (MAC) address printed on the bottom of each
NI EVS-1464RT device to identify individual devices in the configuration environment on the
development machine. You can also assign each NI EVS-1464RT device a descriptive name in the
configuration environment.
Specifications
Refer to the
NI EVS-1464 Series User Manual
for detailed device and I/O specifications.
Environment
NI EVS-1464RT systems are intended for indoor use only.
Maximum altitude..................................................2,000 m
Pollution Degree (IEC 60664) ...............................2
Operating Environment
Ambient temperature range ...................................0 °C to 45 °C
(IEC 60068-2-1 and IEC 60068-2-2)
Relative humidity range (IEC 60068-2-56.............10% to 90% noncondensing
Caution
Clean the NI EVS-1464RT with a soft nonmetallic brush. Make sure that the system is
completely dry and free from contaminants before powering-on the controller again.
Storage Environment
Ambient temperature range ...................................–40 °C to 70 °C
(IEC 60068-2-1 and IEC 60068-2-2)
Relative humidity range (IEC 60068-2-56) ...........5% to 95% noncondensing
Shock and Vibration
Operational shock ..................................................30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC 60068-2-27.
Test profile developed in accordance with
MIL-PRF-28800F.)
Random vibration
Operating .......................................................5 to 500 Hz, 0.3 g
rms
(with solid-state hard drive)
Nonoperating .................................................5 to 500 Hz, 2.4 g
rms
(Tested in accordance with IEC 60068-2-64.
Nonoperating test profile exceeds the requirements
of MIL-PRF-28800F, Class 3.)