Configuring the PDU-2300
The PDU-2300 may be configured for 12 V or 24 V systems. The PDU ships configured for 12 V
systems by default. Complete the following steps to configure the PDU for 24 V systems. See
Figure 2 below for illustration of fuse placement for 12 V and 24 V setup.
1.
Open the PDU cover to expose the various relays and fuses.
2.
Remove 7.5 A fuses from slots F12 and F13 and set aside.
3.
Fill slot F14 (empty by default) with one of the 7.5 A fuses removed in the previous step.
4.
Save the remaining fuse as a replacement.