background image

© 

National Instruments Corporation

3

NI GPIB-Serial Converter Installation Guide

Connect the Hardware

To connect the hardware, complete the following steps:

1. Connect either the GPIB or serial cable between the GPIB-RS232/485/422 

and computer.

2. Connect the DC power plug of the DC power supply to the 

GPIB-RS232/485/422 hardware back panel and plug the power supply into an 
AC outlet.

Caution

Do not operate your GPIB-RS232/485/422 at any voltage other 

than that labelled on the unit. Doing so could damage the unit.

Configure the Hardware

To configure the hardware, complete the following steps:

1. Move the switch on the back panel to the CFG setting.

2. Power on the GPIB-RS232/485/422, using the power switch on the front of the 

product.

The 

PWR

 LED indicator should come on immediately. The 

RDY

 LED 

indicator blinks green after the hardware has passed its power-on self test, 
indicating it is ready for configuration.

3. Launch the NI GPIB-Serial Converter Wizard from 

Start»Programs» 

National Instruments»GPIB-Serial Converter

.

4. Follow the onscreen instructions in the wizard.

For more information, refer to the 

NI GPIB-Serial Converter Help

, available by 

clicking the NI GPIB-Serial Converter Wizard 

Help

 button.

Summary of Contents for GPIB-RS232

Page 1: ...are for more information about troubleshooting problems configuring the hardware and software programming modes of operation and more Check the Hardware Configuration The GPIB RS232 485 422 is shipped with a 100 240 VAC wall mount or desktop power supply If you plan to use a different power source to power your GPIB RS232 485 422 verify that the voltage marked on that power supply matches the inpu...

Page 2: ... change any default setting you must install the NI GPIB Serial Converter software For more information about D Mode settings refer to the NI GPIB Serial Converter Help available after installing the software Install the Software To install the NI GPIB Serial Converter software complete the following steps 1 Log on as Administrator or as a user with administrator privileges 2 Insert the NI GPIB Se...

Page 3: ...age the unit Configure the Hardware To configure the hardware complete the following steps 1 Move the switch on the back panel to the CFG setting 2 Power on the GPIB RS232 485 422 using the power switch on the front of the product The PWR LED indicator should come on immediately The RDY LED indicator blinks green after the hardware has passed its power on self test indicating it is ready for confi...

Page 4: ...nts products refer to the appropriate location Help Patents in your software the patents txt file on your CD or ni com patents 2006 National Instruments Corporation All rights reserved Technical Support The NI GPIB Serial Converter Help is available from the following locations Start Programs National Instruments GPIB Serial Converter The NI GPIB Serial Converter Wizard Help button Refer to the Te...

Reviews: