Caution
Your installation must meet the following requirements for space and
cabling clearance:
•
Allow 25.4 mm (1 in.) on the top and the bottom of the chassis for air
circulation.
•
Allow 50.8 mm (2 in.) in front of modules for cabling clearance for common
connectors, such as the 10-terminal, detachable screw terminal connector.
Figure 3.
cRIO-FRC II Bottom View with Dimensions
29.1 mm
(1.14 in.)
Cabling Clearance
50.8 mm (2.00 in.)
25.4 mm
(1 in.)
63.5 mm
(2.50 in.)
25.4 mm
(1 in.)
63.5 mm
(2.50 in.)
1
178.1 mm
(7.01 in.)
1
64.3 mm
(2.53 in.)
1. Measure ambient temperature here.
Note
Go to
and enter the Info Code
rdcrioconn
to find the minimum
cabling clearance for C Series modules with other connector types.
Figure 4.
cRIO-FRC II Front View with Dimensions
87.3 mm
(3.44 in.)
47.2 mm
(1.86 in.)
30.6 mm
(1.2 in.)
41.1 mm
(1.62 in.)
47.0 mm
(1.85 in.)
4.0 mm
(0.16 in.)
4.0 mm
(0.16 in.)
Cooling Outline
25.4 mm (1 in.)
Cooling Outline
25.4 mm (1 in.)
NI cRIO-FRC II User Manual and Specifications
|