background image

Environmental Management

NI is committed to designing and manufacturing products in an environmentally responsible
manner. NI recognizes that eliminating certain hazardous substances from our products is
beneficial to the environment and to NI customers.

For additional environmental information, refer to the 

Minimize Our Environmental Impact

web page at 

ni.com/environment

. This page contains the environmental regulations and

directives with which NI complies, as well as other environmental information not included in
this document.

Waste Electrical and Electronic Equipment (WEEE)

EU Customers

 

At the end of the product life cycle, all NI products must be

disposed of according to local laws and regulations. For more information about
how to recycle NI products in your region, visit 

ni.com/environment/weee

.

Battery Replacement and Disposal

Cd/Hg/Pb

Battery Directive

 

This device contains a long-life coin cell battery. If you need to

replace it, use the Return Material Authorization (RMA) process or contact an
authorized National Instruments service representative. For more information about
compliance with the EU Battery Directive 2006/66/EC about Batteries and
Accumulators and Waste Batteries and Accumulators, visit 

ni.com/environment/

batterydirective

.

电子信息产品污染控制管理办法(中国

RoHS

中国客户

 

National Instruments

符合中国电子信息产品中限制使用某些有害物

质指令(

RoHS

)。关于

National Instruments

中国

RoHS

合规性信息,请登录

ni.com/environment/rohs_china

。(

For information about China RoHS

compliance, go to 

ni.com/environment/rohs_china

.

)

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

, you have

access to everything from troubleshooting and application development self-help resources to
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and

other services.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

NI cRIO-FRC II User Manual and Specifications

  | 

© National Instruments

  | 

21

Summary of Contents for cRIO-FRC II

Page 1: ...FIRST Robotics Competition Figure 1 cRIO FRC II Front Panel 1 2 3 5 4 1 LEDs 2 RJ 45 Ethernet Port 3 Power Connector 4 Reset Button 5 RS 232 Serial Port This document describes how to connect the cRIO...

Page 2: ...has been switched off or the area is known to be nonhazardous Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous Caution Substitution of component...

Page 3: ...National Instruments could void your authority to operate it under your local regulatory rules Special Conditions for Marine Applications Some products are Lloyd s Register LR Type Approved for marin...

Page 4: ...rg community frc and select Documents and Updates Competition Manual and Related Documents Mounting the CompactRIO Reconfigurable Embedded Chassis You can mount the chassis horizontally on a flat vert...

Page 5: ...ing Clearance 50 8 mm 2 00 in 25 4 mm 1 in 63 5 mm 2 50 in 25 4 mm 1 in 63 5 mm 2 50 in 1 178 1 mm 7 01 in 1 64 3 mm 2 53 in 1 Measure ambient temperature here Note Go to ni com info and enter the Inf...

Page 6: ...before mounting it Mounting the Chassis on a Panel Panel or wall mounting is the best method for applications that are subject to high shock and vibration You can use the NI 9904 panel mount kit to mo...

Page 7: ...ws that are appropriate for the wall surface The maximum screw size is M4 or number 8 Mounting the Chassis Directly on a Flat Surface Using the Mounting Holes Panel or wall mounting is the best method...

Page 8: ...Chassis on a DIN Rail You can order the NI 9912 DIN rail mount kit if you want to mount the chassis on a DIN rail You need one clip for mounting the chassis on a standard 35 mm DIN rail Complete the...

Page 9: ...the spring until the clip locks in place on the DIN rail Mounting the Chassis on a Desktop Using the NI 9901 Desktop Mounting Kit You can use the NI 9901 desktop mounting kit to mount the chassis on a...

Page 10: ...9 mm 0 90 in Complete the following steps to install a C Series I O module in the chassis 1 Make sure that no I O side power is connected to the I O module If the system is in a nonhazardous location...

Page 11: ...wer is connected to the I O module If the system is in a nonhazardous location the chassis power can be on when you remove I O modules 2 Squeeze the latches on both sides of the module and pull the mo...

Page 12: ...Power Requirements section The cRIO FRC II filters and regulates the supplied power and provides power for all of the I O modules The cRIO FRC II has one layer of reverse voltage protection Complete...

Page 13: ...ts solid yellow indicating that the cRIO FRC II is in safe mode Refer to the MAX help for information about safe mode Controller Startup Options You can configure the following controller startup opti...

Page 14: ...ller either with or without cycling power Connecting Serial Devices to the cRIO FRC II The cRIO FRC II has an RS 232 serial port to which you can connect devices such as displays or input devices Use...

Page 15: ...the chassis Refer to the Measurement Automation Explorer Help for information about installing software on the chassis 3 The chassis is in safe mode Refer to the Measurement Automation Explorer Help f...

Page 16: ...erial port terminal to read the IP address of the controller If you want the controller to attempt a new DHCP connection proceed to step 2 2 Press and hold the Reset button for 5 s then release it The...

Page 17: ...ractices for using nonvolatile memory go to ni com info and enter the Info Code SSDBP Reconfigurable FPGA FPGA type Xilinx Spartan 6 LX 45 Number of flip flops 54 576 Number of 4 input LUTs 27 288 Num...

Page 18: ...lb in Dimensions unloaded 178 1 mm 87 3 mm 64 3 mm 7 0 in 3 4 in 2 5 in Weight 643 g 22 7 oz Safety Voltages Connect only voltages that are within the following limits V terminal to C terminal 30 V m...

Page 19: ...9 0 2012 EN 60079 15 2010 IEC 60079 0 Ed 6 IEC 60079 15 Ed 4 UL 60079 0 Ed 5 UL 60079 15 Ed 3 CSA 60079 0 2011 CSA 60079 15 2012 Note For UL and other safety certifications refer to the product label...

Page 20: ...on To meet these specifications you must panel mount the system Operating vibration Random IEC 60068 2 64 5 grms 10 Hz to 500 Hz Sinusoidal IEC 60068 2 6 5 g 10 Hz to 500 Hz Operating shock IEC 60068...

Page 21: ...If you need to replace it use the Return Material Authorization RMA process or contact an authorized National Instruments service representative For more information about compliance with the EU Batte...

Page 22: ...rademarks and Logo Guidelines at ni com trademarks for information on NI trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For pat...

Reviews: