background image

 

CVI, LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the 
Eagle logo are trademarks of National Instruments Corporation. Refer to the 

Trademark Information 

at

 

ni.com/trademark

s

 for other National Instruments trademarks. The mark LabWindows is used 

under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft 
Corporation in the United States and other countries. Other product and company names mentioned 
herein are trademarks or trade names of their respective companies. For patents covering 
National Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your 

software, the 

patent

s

.txt

 file on your media, or the 

National Instruments Patent Notice

 

at

ni.com/patent

s

.

© 2009–2010 National Instruments Corporation. All rights reserved.

372620B-01

May10

Where to Go for Support

The National Instruments Web site is your complete resource for technical 
support. At 

ni.com/

s

upport

 you have access to everything from 

troubleshooting and application development self-help resources to email 
and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world to help 
address your support needs. For telephone support in the United States, 
create your service request at 

ni.com/

s

upport

 and follow the calling 

instructions or dial 512 795 8248. For telephone support outside the United 
States, contact your local branch office:

Australia 1800 300 800, Austria 43 662 457990-0, 
Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, 
Canada 800 433 3488, China 86 21 5050 9800, 
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, 
Finland 358 (0) 9 725 72511, France 01 57 66 24 24, 
Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, 
Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400, 
Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710, 
Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466, 
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, 
Poland 48 22 328 90 10, Portugal 351 210 311 210, 
Russia 7 495 783 6851, Singapore 1800 226 5886, 
Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197, 
Spain 34 91 640 0085, Sweden 46 (0) 8 587 895 00, 
Switzerland 41 56 2005151, Taiwan 886 02 2377 2222, 
Thailand 662 278 6777, Turkey 90 212 279 3031, 
United Kingdom 44 (0) 1635 523545

Summary of Contents for 9235

Page 1: ...ions You can install these help files when you install NI DAQmx on the calibration computer Contents Conventions 2 Software 2 Documentation 3 Calibration Interval 3 Test Equipment 4 Test Conditions 4 Calibration Procedure 5 Calibration Process Overview 5 Initial Setup 5 Connecting the Calibrator to the Module 6 Verification Procedures 8 Measurement Accuracy Verification 8 Shunt Calibration Accurac...

Page 2: ...his font is also used for the proper names of disk drives paths directories programs subprograms subroutines device names functions operations variables filenames and extensions monospace italic Italic text in this font denotes text that is a placeholder for a word or value that you must supply Software Install NI DAQmx 8 8 or later on the calibration computer NI DAQmx includes high level function...

Page 3: ...that your device is operating properly To access this guide select Start All Programs National Instruments NI DAQ DAQ Getting Started Guide Note The documents above are installed with NI DAQmx You can also download the latest versions from the NI Web site at ni com manuals NI 9235 9236 Operating Instructions and Specifications This document describes how to use the NI 9235 9236 and includes specif...

Page 4: ...t 10 minutes to ensure that the measurement circuitry is at a stable operating temperature Table 1 Recommended Equipment Equipment Recommended Model Requirements Calibrator Fluke 5500A If this instrument is unavailable use a calibrator with generation of resistances in the ranges of 108 Ω 132 Ω and 315 Ω 385 Ω with 0 01 Ω resolution an accuracy of at least 90 ppm and automatic lead wire compensati...

Page 5: ...e operates within its specifications after adjustment The first two steps are explained in the following sections Initial Setup You must configure the device in Measurement Automation Explorer MAX to communicate with NI DAQmx Complete the following steps to configure a device in MAX 1 Install the NI DAQmx driver software 2 Make sure that no power is connected to the module terminals If the system ...

Page 6: ... the module channel you want to verify Leave all other channels unconnected Note The three connections to the calibrator LO terminal must be connected at the calibrator output jack Note Ensure that the connection resistance between the calibrator LO terminal and the module RC terminal meets the requirement listed in Table 1 4 Connect the HI terminal of the calibrator to the EXC0 terminal of the mo...

Page 7: ...ator to Module Connections Refer to Figure 2 for the terminal assignments of the NI 9235 9236 Figure 2 NI 9235 9236 Terminal Assignments Fluke 5500A AUX HI EXC1 EXC0 AI0 RC0 AUX LO HI LO NI 9235 9236 EXC0 AI0 RC0 EXC2 AI2 RC2 EXC4 AI4 RC4 EXC6 AI6 RC6 EXC1 AI1 RC1 EXC3 AI3 RC3 EXC5 AI5 RC5 EXC7 AI7 RC7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ...

Page 8: ...ed test coverage You can verify the following for NI 9235 9236 modules measurement accuracy shunt calibration accuracy excitation voltage Measurement Accuracy Verification Complete the following steps to test the measurement accuracy of the device 1 Zero the calibrator with the ohms only zero OHMS ZERO operation Refer to the calibrator documentation for more information about zeroing the calibrato...

Page 9: ...or the correct instance to use for polymorphic VIs LabVIEW Block Diagram NI DAQmx Function Call LabVIEW does not require this step Call DAQmxCreateTask with the following parameters taskName AIVerificationTask taskHandle taskHandle LabVIEW Block Diagram NI DAQmx Function Call Call DAQmxCreateAIVoltageChan WithExcit with the following parameters taskHandle taskHandle physicalChannel dev1 aix nameTo...

Page 10: ... Start Task VI as shown in the following table LabVIEW Block Diagram NI DAQmx Function Call CallDAQmxCfgSampClkTiming with the following parameters taskHandle taskHandle source NULL rate 5000 sampleMode DAQmx_Val_FiniteSamps sampsPerChan 5000 LabVIEW Block Diagram NI DAQmx Function Call Call DAQmxSetAIBridgeShuntCal Enable with the following parameters taskHandle taskHandle channel NULL data FALSE...

Page 11: ...es although you can save time by verifying only the values used in your application 14 Perform the following calculation for each test result value other than 0 V V using the results you recorded in step 11 Test Result 0 V V Test Result LabVIEW Block Diagram NI DAQmx Function Call Call DAQmxReadAnalogF64 with the following parameters taskHandle taskHandle numSampsPerChan 1 timeout 10 0 fillMode DA...

Page 12: ...e DMM and 4 wire resistance measurement connections measure the resistance of the wire to be connected between the calibrator LO terminal and the module RC terminal and record the result for later use You must do this because this connection to the module creates a lead wire desensitization error This results in module readings that are systematically lower than the true shunt calibration output K...

Page 13: ...or the correct instance to use for polymorphic VIs LabVIEW Block Diagram NI DAQmx Function Call LabVIEW does not require this step Call DAQmxCreateTask with the following parameters taskName SCVerificationTask taskHandle taskHandle LabVIEW Block Diagram NI DAQmx Function Call Call DAQmxCreateAIVoltageChan WithExcit with the following parameters taskHandle taskHandle physicalChannel dev1 aix nameTo...

Page 14: ... Start Task VI as shown in the following table LabVIEW Block Diagram NI DAQmx Function Call CallDAQmxCfgSampClkTiming with the following parameters taskHandle taskHandle source NULL rate 5000 sampleMode DAQmx_Val_FiniteSamps sampsPerChan 10000 LabVIEW Block Diagram NI DAQmx Function Call Call DAQmxSetAIBridgeShuntCal Enable with the following parameters taskHandle taskHandle channel NULL data FALS...

Page 15: ...following calculation using the results you recorded in step 11 ResultSCE ResultSCD 1 Rwire Rcomp where ResultSCE result with shunt calibration enabled ResultSCD result with shunt calibration disabled Rwire wire resistance measured in step 1 Rcomp 120 Ω for the NI 9235 and 350 Ω for the NI 9236 LabVIEW Block Diagram NI DAQmx Function Call Call DAQmxReadAnalogF64 with the following parameters taskH...

Page 16: ...BY 18 Disconnect the calibrator from the device Excitation Voltage Verification The excitation source of the NI 9235 9236 is common to all eight input channels so you need to verify excitation voltage on only one channel Complete the following steps to verify the excitation voltage 1 Connect the positive input of the DMM to any EXC terminal of the module and the negative input of the DMM to any RC...

Page 17: ...owing calibration specifications are for 23 5 C Table 2 NI 9235 9236 Measurement Accuracy Module Percent of Reading Gain Error Percent of Range Offset Error NI 9235 9236 0 04 max 0 002 max Range equals 29 4 mV V Table 3 NI 9235 9236 Shunt Calibration Accuracy Module Percent of Reading Gain Error NI 9235 0 22 max NI 9236 0 20 max Table 4 NI 9235 9236 Excitation Voltage Accuracy Module Accuracy NI 9...

Page 18: ...For accuracy verification Upper Limits and Lower Limits are given in units of V V for verification and units of με for reference Table 5 NI 9235 Measurement Accuracy Verification Test Limits Calibrator Output Ω Nominal Value V V Nominal Value με 1 Year Limits Lower Limit V V Upper Limit V V Lower Limit με Upper Limit με 120 0 0 108 0 0263158 50 000 0 0263048 0 0263268 49 980 1 50 019 9 114 0 01282...

Page 19: ...25 011 3 385 0 0238095 50 000 0 0237995 0 0238195 49 977 8 50 022 1 Note The Upper and Lower Limit V V values are commonly used for verification The Upper and Lower Limit με values are for reference Table 7 NI 9235 9236 Shunt Calibration Accuracy Verification Test Limits Module Nominal Value μV V Nominal Value με 1 Year Limits Lower Limit μV V Upper Limit μV V Lower Limit με Upper Limit με NI 9235...

Page 20: ...NI Application Engineers National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or dial 512 795 8248 For telephone suppor...