background image

 

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. 
Refer to the 

Terms of Use

 section on 

ni.com/legal

 for more information about National 

Instruments trademarks. Other product and company names mentioned herein are trademarks or trade 
names of their respective companies. For patents covering National Instruments products/technology, 
refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your 

media, or the 

National Instruments Patent Notice

 at 

ni.com/patents

.

© 2009 National Instruments Corporation. All rights reserved.

371818B-01

Apr09

electricity meters and measurements on primary overcurrent 
protection devices and on ripple control units.

Where to Go for Support

The National Instruments Web site is your complete resource for technical 
support. At 

ni.com/support

 you have access to everything from 

troubleshooting and application development self-help resources to email 
and phone assistance from NI Application Engineers.

A Declaration of Conformity (DoC) is our claim of compliance with the 
Council of the European Communities using the manufacturer’s 
declaration of conformity. This system affords the user protection for 
electromagnetic compatibility (EMC) and product safety. You can obtain 
the DoC for your product by visiting 

ni.com/certification

. If your 

product supports calibration, you can obtain the calibration certificate for 
your product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world to help 
address your support needs. For telephone support in the United States, 
create your service request at 

ni.com/support

 and follow the calling 

instructions or dial 512 795 8248. For telephone support outside the United 
States, contact your local branch office: 

Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, 
Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800, 
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, 
Finland 358 (0) 9 725 72511, France 01 57 66 24 24, Germany 49 89 7413130, 
India 91 80 41190000, Israel 972 3 6393737, Italy 39 02 41309277, 
Japan 0120-527196, Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28, 
Malaysia 1800 887710, Mexico 01 800 010 0793, 
Netherlands 31 (0) 348 433 466, New Zealand 0800 553 322, 
Norway 47 (0) 66 90 76 60, Poland 48 22 328 90 10, Portugal 351 210 311 210, 
Russia 7 495 783 6851, Singapore 1800 226 5886, Slovenia 386 3 425 42 00, 
South Africa 27 0 11 805 8197, Spain 34 91 640 0085, 
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, 
Taiwan 886 02 2377 2222, Thailand 662 278 6777, Turkey 90 212 279 3031, 
United Kingdom 44 (0) 1635 523545

Summary of Contents for 779640-01

Page 1: ...ata acquisition DAQ device Introduction The NI USB 6525 is a full speed USB 2 0 device that provides eight 60 VDC channel to channel isolated digital inputs DI eight 60 VDC 30 Vrms channel to channel...

Page 2: ...s Getting Started Guide that shipped with your device and is also accessible from Start All Programs National Instruments NI DAQ for more information Note For information about non Windows operating s...

Page 3: ...You can apply the signal labels on the screw terminal blocks for easy signal identification 2 Refer to Table 1 and Figure 4 for label orientation and affix provided signal labels to the screw terminal...

Page 4: ...auge between 16 AWG 28 AWG Table 1 Digital Terminal Assignments Module Terminal Signal Module Terminal Signal 1 P0 0A 17 P1 0 2 P0 0B 18 P1 0 3 P0 1A 19 P1 1 4 P0 1B 20 P1 1 5 P0 2A 21 P1 2 6 P0 2B 22...

Page 5: ...specified interval Intermediate length pulses pulses longer than half of the interval but less than the interval may or may not pass the filter The filter operates on the inputs from the optocouplers...

Page 6: ...equal to one half of the specified timing interval The input signal is sampled on each rising edge of the sample clock which is every 40 s1 A change in the input signal is recognized only if it mainta...

Page 7: ...ou can program the NI 6525 to send an interrupt when a change occurs on any input line The NI 6525 can monitor changes on selected input lines or on all input lines It can monitor for rising edges 0 t...

Page 8: ...g edges on the sensor which correspond to over limit conditions Bit 0 is connected to a switch The software can react to any switch closure which is represented by a falling edge If the switch closure...

Page 9: ...set software command within the time specified for the watchdog timer the outputs go to a user defined safe state and remain in that state until the watchdog timer is disarmed by the application and n...

Page 10: ...tions for a power supply and load connected to an isolated input Figure 6 Connecting a Power Supply and Load to the Isolated Input Caution Use twisted pair field wiring to reduce EMC noise In Figure 6...

Page 11: ...ution Use twisted pair field wiring to reduce EMC noise Power On and Power Off Conditions The default power on state of the solid state relays is open By default the solid state relays remain open whe...

Page 12: ...ct DC inductive loads and an MOV to protect AC inductive loads respectively Figure 8 Contact Protection for DC Inductive Loads Figure 9 Contact Protection for AC Inductive Loads Inductive Load USB 652...

Page 13: ...an RL value small enough to provide the necessary source current but large enough to reduce sink current and to avoid consuming unnecessary power Many TTL level applications use an RL value of 5 k Ev...

Page 14: ...ypical Solid State Relay Outputs Number of output channels 8 ch ch isolated Relay type Normally open solid state relay SSR Switching voltage 60 VDC 30 Vrms max Switching current per channel 500 mA max...

Page 15: ...state Active current 150 mA max Suspend current 350 A typ Physical Characteristics Dimensions Without connectors 6 35 cm 8 51 cm 2 31 cm 2 50 in 3 35 in 0 91 in With connectors 8 18 cm 8 51 cm 2 31 cm...

Page 16: ...60 VDC continuous Withstand 60 VDC continuous Caution Do not use this module for connection to signals or for measurements within Measurement Categories II III or IV Hazardous Locations The USB 6525 i...

Page 17: ...ows 2006 95 EC Low Voltage Directive safety 2004 108 EC Electromagnetic Compatibility Directive EMC Online Product Certification Refer to the product Declaration of Conformity DoC for additional regul...

Page 18: ...nd cables specified in the installation instructions You must have all covers and filler panels installed during operation of the device Do not operate the device in an explosive atmosphere or where t...

Page 19: ...e measurements include signal levels special equipment limited energy parts of equipment circuits powered by regulated low voltage sources and electronics Measurement Category II is for measurements p...

Page 20: ...an obtain the DoC for your product by visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration National Inst...

Reviews: