Installation and Connections
Chapter 5
SC-207X Series User Manual
5-8
© National Instruments Corporation
Signal Connections
Ribbon Cable Connectors
The pinout for the 50-pin ribbon cable connector on the SC-2070 board is exactly the same as the
50-pin connector on the MIO-16 board. The pinout for the 50-pin ribbon cable connector on the
SC-2071 board is exactly the same as the 50-pin connector on the Lab/1200 device. The pinout for the
50-pin ribbon cable connector on the SC-2072 board is exactly the same as the 50-pin connector on the
host DAQ device. For more information on these connectors, refer to your DAQ device’s user manual.
Table 5-2 lists SC-207X Series compatibility with the SC-205X Series boards.
Table 5-2. SC-205X Series Board Connectors Compatible with the SC-207X Series Boards
Connectors
Connections
Description
J1, J2
50-pin male connectors
SC-2050 (for MIO-16 boards)
One of these must attach to the
host MIO-16 board. The other
connection can attach to the
SC-2070 board.
J1, J2
50-pin male connectors
SC-2053 (for Lab/1200 boards)
One of these must attach to the
host Lab/1200 board. The other
connection can attach to the
SC-2071 board.
J1, J2
50-pin male connectors
SC-205X Series boards
One of these must attach to the
host DAQ device. The other
connection can attach to the
SC-2072 board.
Warning:
Do not attempt to connect an SC-207X Series board to any connector for which it is not designed.
Such connections can result in damage to any or all of the boards connected to the SC-207X
Series board, to the host computer, and to the SC-207X Series boards themselves. National
Instruments is
NOT
liable for any damages resulting from such misuse.
Screw Terminal Connections for the SC-2070 and the SC-2071
The SC-2070 and SC-2071 boards supply analog input to the host computer (via the DAQ device) via
the screw terminals along one edge of the board. The remaining signals from the DAQ device are
available at screw terminals on the other side of the board. Additionally, eight undedicated screw
terminals are located adjacent to the general-purpose breadboarding area. Guidelines for connections
to the analog input terminals are given in Chapters 2 and 3.
Warning:
Connections, including power signals to ground and vice versa, that exceed any of the
maximum input or output voltage ratings on the SC-207X Series boards can result in
damage to any or all of the boards connected to the SC-207X Series boards, to the host
computer, and to the SC-207X Series boards. Overvoltage conditions also can present a
shock hazard to you. National Instruments is
NOT
liable for any damages or injuries
resulting from incorrect signal connections.