background image

Eyes

All versions of DANi  

come with 3 sets of 

brown eyes . 1 set of 

normal pupil brown eyes, 

1 set of constricted pupil 

brown eyes and 1 set of 

dilated pupil brown eyes . 

The normal eyes come 

installed in the head . The 

eyes can be changed to dilated or constricted by 

creasing the skin at the outside of each eye and 

rolling the eye up . (See Figure 3 .) Both eyes may 

be irrigated using water . Eye sockets will hold no 

more than a few drops of liquid at a time . Following 

completion of the exercise, follow the above 

instructions for removing the eye, dry the sockets 

completely with a soft cloth, and replace the eyes .

Oral Hygiene

Tooth brushing should be simulated without water 

or any cleaning agents to avoid leaking into the 

head of the manikin and to simplify cleanup . Teeth 

cannot be flossed .

Note: All Versions of DANi come packaged with 

the normal eyes, and female genitalia installed . 

The Patient Skills Trainer and Simulator come with 

lungs, stomach, and other internal reservoir bags 

installed .

Arms / Joints

DANi is packaged with 

arms and female genitalia 

attached and legs 

unattached to prevent 

damage during shipping . 

Refer to the following 

sections for assembly 

instructions (See Figure 1) .

Leg Assembly

The legs attach to 

the body at the hips 

by rotating the legs 

backward approximately 

150° so the feet are near 

the shoulders and the 

keyholes are aligned .  

(See Figure 2) .

Set Up 

Arms / Joints / Legs / Eyes / Oral Hygiene

Fig 1.

Fig 2.

Fig 3.

8

Summary of Contents for DANi LF04500

Page 1: ...DANi Patient Care Trainer LF04500 LF04500M Patient Skills Trainer LF04502 LF04502M Patient Simulator LF04504 LF04504M Patient Simulator Export LF04504EX LF04504MEX INSTRUCTION MANUAL...

Page 2: ...my Care Lavage and Gavage 14 Male Catheterization 15 Foreskin Application Prostate Examination 16 Female Catheterization 17 Enema Administration 18 Female Cervical Exam 18 Suprapubic and Urinary Cathe...

Page 3: ...l patient for lifting and carrying Each version is affordable and durable with upgradable items DANi Teen Young Adult Patient Care Trainer General patient care daily living assistance simulation platf...

Page 4: ...uded Soft Male and Female Genitalia Normal and Cancerous Moles Stage 1 Sacral Ulcer Bandaging and Wound Dressing Recommended bandages Silicone Adhesive Bandages Patient Positioning fully articulated A...

Page 5: ...stration Left Blood Pressure Arm with Radial Pulse Injection Sites arms thigh right side buttocks supporting IM and sub cutaneous injections Gastrostomy Procedures lavage gavage tube placement Nasogas...

Page 6: ...re Urinary Catheter Care No aux equipment Stomas Standard Arms with Injection Sites Support for Oxygen Administration Left Blood Pressure Arm Option Advanced Skills Injections Sites Gastrostomy Proced...

Page 7: ...g Self Harm LF04527 Bruising Drug Use LF04526 List of Components Female Genitalia SANE LF04514 Light LF04514M Medium DANi Teen Young Adult Patient Simulator LF04504 LF04504M includes monitors DANi Tee...

Page 8: ...Hygiene Tooth brushing should be simulated without water or any cleaning agents to avoid leaking into the head of the manikin and to simplify cleanup Teeth cannot be flossed Note All Versions of DANi...

Page 9: ...ment Features included with LF04502 LF04502M LF04504 LF04504M and LF04504EX LF04504MEX Fig 6 Set Up Ear Care Bath Washing Tracheostomy Care Ear Care Both ears may be irrigated Using water to perform e...

Page 10: ...ntinue to prevent backflow into the head of the manikin Features included with LF04502 LF04502M LF04504 LF04504M and LF04504EX LF04504MEX Fig 7 Set Up Lavage Gavage Suctioning Nasogastric Carotid Puls...

Page 11: ...loop Insert the tubes back into the torso of the manikin and replace the head on the torso See Figure 14 2 Lubricate nasogastric devices and supplies being used with the Pump Spray Lubricant provided...

Page 12: ...ing a laryngoscope blade As with a real human See Figure 21 damage can be caused if improper forces and techniques are used Damaged caused by improper use will void the warranty Note There is no crico...

Page 13: ...a reservoirs See Figure 22 1 Remove the genitalia and reach through the genital cavity It is recommended to suction the fluid from the bag prior to removal to prevent spillage when removing for cleani...

Page 14: ...coupler body with bag attached onto the coupler insert part with the black O ring that is protruding from the underside of the gastrostomy inside the upper torso of the manikin You will hear a slight...

Page 15: ...Fig 30 Fig 27 Note The Fluid Supply Stand is not included Use distilled water or follow instructions on the Simulated Urine 4 Lubricate the catheter being used with the Pump Spray Lubricant provided S...

Page 16: ...te examination Following the procedure rinse the rectum with warm water and allow to dry prior to storing Note The male genital insert does not have the capacity for enema administration Must use fema...

Page 17: ...enitalia to remove any residual lubricant Fluids should be drained and the reservoir emptied after every use Ensure the reservoir is clean and dry prior to storing Female Catheterization Enema Inserti...

Page 18: ...enema reservoir holds up to 200cc of fluid Fig 41 Set Up Enema Administration Female Cervical Examination Features included with LF04502 LF04502M LF04504 LF04504M and LF04504EX LF04504MEX The female...

Page 19: ...ubricate the catheter being used with the Pump Spray Lubricant provided The catheter should be well lubricated and force should not be used when placing the tube After completion of the exercise 1 Clo...

Page 20: ...splay window are three buttons Menu Gap and Calibrate Blood Pressure Arm Features included with LF04502 LF04502M LF04504 LF04504M and LF04504EX LF04504MEX Installing the Batteries 1 Take the Blood Pre...

Page 21: ...will display in the Electronic Control Unit window See Figure 55 6 Use the up or down arrow keys located to the right of the menu button to adjust the diastolic pressure Note The systolic and diastoli...

Page 22: ...e pulse will automatically turn off when the cuff is inflated and surpasses the systolic set point It will turn on when the cuff is deflated 20 mmHg below the diastolic set point This function allows...

Page 23: ...and the main menu window will be displayed Set Up Blood Pressure Arm Fig 60 Fig 61 Performing a Blood Pressure 1 Verify the pressure line tubing from the sphygmomanometer and the audio line from the a...

Page 24: ...with the assembled sphygmomanometer 3 Obtain a new sphygmomanometer 4 Using a scissors carefully cut the tube of the sphygmomanometer about 2 from the gauge See Figure 62 5 Take the T fitting and inse...

Page 25: ...he pint bottle containing the synthetic blood concentrate with distilled water 2 Close the clamp on the IV tubing and pour the synthetic blood into one of the provided fluid supply bags This will be I...

Page 26: ...t IV needle or butterfly 7 To start the IV flow open the clamps on both IV Bags A and B Proof of proper procedure will be evidenced by the flow of fluid from IV Bag A Control flow rate with the clamp...

Page 27: ...edures and ensure clamps are open on appropriate fluid supply IV bags and or shoulder tubes 2 Look over your equipment prior to use IV tubes will kink at the clamp site with repeated use Routinely mov...

Page 28: ...aining the shoulder joint to the arm 2 Peel the skin down and remove from arm See Figure 69 3 Apply baby powder to the interior of the replacement skin and pull onto the arm 4 The key feature needs to...

Page 29: ...recautions 1 This synthetic blood is specially formulated to be compatible with the self sealing veins and plastics used in manufacturing the injectable training arm 2 NEVER use synthetic blood for in...

Page 30: ...eries into SmartScope and 2 AAA batteries into the remote control The compartments are marked as to the positions of the batteries or 4 Press the red power button on the remote control This turns on t...

Page 31: ...e speaker cord into the speaker jack on top of the SmartScope box 3 Plug the amplifier speaker into the 110V or 220V power source 4 When the speaker is connected the SmartScope earpieces will not work...

Page 32: ...ic presystolicmurmurs loud1stsound 5 Holosystolic Murmur Normal Normal Normal Normal Patienthasmitralregurgitation frequent prematureventricularcontractions Murmuriscrescendo decresendowithlate peakin...

Page 33: ...i Ronchi Ronchi Ronchi 8 Stridor Stridor Stridor StridorLowerVolume StridorLowerVolume 9 Cavernous Cavernous Cavernous Cavernous Cavernous 10 Bronchovesicular Tracheal Bronchovesicular NormalVesicular...

Page 34: ...en opening on the foot sleeve See Figure 83 Proper Application Shown See Figure 84 Set Up Pressure Injury Wounds Set Up Edema Edema Features included with LF04502 LF04502M LF04504 LF04504M and LF04504...

Page 35: ...oid imlabworld com heartisensestudent Apple Device https apps apple com us app cpr add on kitinstructor id1203164623 https apps apple com us app cpr add on kitstudent id1400115591 Powering on CPR Moni...

Page 36: ...Set Up Identifying Parts and Consumables 36 36 20 22 23 19 21 1 7 6 25 26 4 29 30 31 34 33 37 39 38 41 42 43 40 44 46 35 36 27 28 32 14 16 17 18 15 9 3 5 12 13 2 11 10 Arm Skin 24 45...

Page 37: ...t Leg Skin Medium 16 LF04518 Right Arm Skin Light LF04518M Right Arm Skin Medium 17 LF04519 Left Arm Skin Light LF04519M Left Arm Skin Medium 18 LF04521 Torso Skin Light LF04521M Torso Skin Medium 19...

Page 38: ...use Cautions Solvents or corrosive materials will damage the simulator Never place the simulator on any kind of printed paper or plastic These materials will transfer indelible stains Ball point pens...

Page 39: ...YEARS 5 Up to 5 years warranty...

Page 40: ...Nasco Healthcare 16 Simulaids Drive Saugerties NY 12477 1 833 NASCOHC 627 2642 info nascohealthcare com www nascohealthcare com PC 101038 02 23 2023 Nasco Healthcare...

Reviews: