4 . Lubricate the catheter
being used with the
Pump Spray Lubricant
provided (See Figure 40) .
The catheter should
be well lubricated and
force should not be
used when placing
the tube .
Note: Special care should be taken when using a
Foley catheter . Nasco Healthcare recommends use
of 16 French Foley catheters . use of this size will
avoid the possibility of leakage . Cuff inflation should
only be attempted when the catheter is in the
proper position inside the bladder . The cuff must
also be completely deflated before the catheter is
removed . The catheter should not be left inserted
in the simulator for an extended period of time .
Improper use of a Foley catheter may result in
damage to the simulator and void the warranty .
5 . After completion of the exercise, close the clamp
on the Fluid Supply Bag tubing and remove the
female genital insert by reversing the assembly
instructions . Disconnect the urinary catheter
reservoir tubing via the quick disconnect, remove
the reservoir from the female genitalia insert,
and drain the reservoir thoroughly .
6 . Rinse the reservoir and the outside of the female
genitalia to remove any residual lubricant .
Fluids should be drained and the reservoir emptied
after every use . Ensure the reservoir is clean and dry
prior to storing .
Female Catheterization,
Enema Insertion &
Cervical Examination
Features included with
LF04502/LF04502M,
LF04504/LF04504M, and
LF04504EX/LF04504MEX .
To change genitals in the
simulator, simply press to
fit into the open genital
area of the pelvis . (See Figure 36) .
The urinary catheterization reservoir is
interchangeable between male and female genitals .
Female Genitals come installed with the simulator .
To prepare for catheterization exercises:
1 . The urinary reservoir
is installed on the
back side, make sure
the urinary reservoir
is firmly in place . (See
Figure 37) .
2 . . Close the clamp on
the Fluid Supply Bag
(See Figure 38) and
fill with water or
included simulated
urine . Recommended
amount of fluid to fill
the Fluid Supply Bag is
between 100 and 250 ML .
3 . Hang the filled Fluid
Supply Bag . Attach
the tubing quick
connect on end of
Fluid Supply Bag to the
quick connect on the
left lower side of the
simulator’s torso . Open
clamp on fluid supply
bag (See Figure 39) .
Note: The Fluid Supply
Stand is not included .
Use distilled water or
follow instructions on the Simulated Urine .
Set Up
Female Catheterization
Fig 40.
Fig 39.
Fig 36.
Fig 38.
Fig 37.
17