Male Catheterization
& Prostate Examination
Features included with
LF04502/LF04502M,
LF04504/LF04504M, and
LF04504EX/LF04504MEX .
The male genital
insert can represent
an uncircumcised or
circumcised adult male,
with the addition of the included foreskin . To
change genitals in the simulator, simply press to fit
into the open genital area of the pelvis . (See Figure 29) .
The urinary catheterization reservoir is
interchangeable between male and female genitals .
Female Genitals come installed with the simulator .
Note: To apply the foreskin, apply the included pump
spray lubricant to the glans and slide the foreskin in
place . To prepare for catheterization exercises:
1 . The urinary reservoir
is installed on the
back side, make sure
the urinary reservoir
is firmly in place . (See
Figure 28) .
2 . Close the clamp on
the Fluid Supply Bag
(See Figure 29) and
fill with water or
included simulated
urine . Recommended
amount of fluid to fill
the Fluid Supply Bag
is between 100 and
250 mL .
3 . Hang the filled Fluid
Supply Bag . Attach the
tubing quick connect
on end of Fluid Supply Bag to the quick connect
on the left lower side of the simulator’s torso .
Open Clamp on fluid supply bag (See Figure 30) .
Set Up
Male Catheterization
Fig 31.
Fig 30.
Fig 27.
Note: The Fluid Supply
Stand is not included .
Use distilled water or
follow instructions on
the Simulated Urine .
4 . Lubricate the
catheter being used
with the Pump Spray
Lubricant provided
(See Figure 31) . The
catheter should be
well lubricated and
force should not be
used when placing
the tube .
Note: Special care
should be taken when
using a Foley catheter .
Nasco Healthcare
recommends use of
16 French Foley catheters . Use of this size will avoid
the possibility of leakage . Cuff inflation should only
be attempted when the catheter is in the proper
position inside the bladder . The cuff must also be
completely deflated before the catheter is removed .
The catheter should not be left inserted in the
simulator for an extended period of time . Improper
use of a Foley catheter may result in damage to the
simulator and void the warranty .
5 . After completion of the exercise, close the clamp
on the Fluid Supply Bag tubing and remove the
male genital insert by reversing the assembly
instructions . Disconnect the urinary catheter
reservoir tubing via the quick disconnect, remove
the reservoir from the male genitalia insert, and
drain the reservoir thoroughly (See Figure 28) .
6 . Rinse the reservoir and the outside of the male
genitalia to remove any residual lubricant .
Fluids should be drained and the reservoir emptied
after every use . Ensure the reservoir is clean and dry
prior to storing .
Fig 29.
Fig 28.
15