Set Up
IV and Injection Arm
IV and Injection Arm
Features included with LF04502/LF04502M,
LF04504/LF04504M, and LF04504EX/LF04504MEX .
DANi has skin texture realistic to touch thanks
to modern plastics technology . The following
adhesives will alleviate challenges in adhesion:
3M Kind Removal Adhesive Tape, Safe N Simple
Silicone Adhesive Tape, Curad Silicone Band-
Aid, Safe N Simple Simpurity IV Derm Silicone
(Tegaderm equivalent) .
Internal and External Structure
The outer skin is easily peeled off, revealing the
“core” and veins . The skin and veins can be readily
replaced when needed . Using smaller gauge
needles will prolong the life of the original skin and
veins . Replacement parts are available and listed
at the end of this manual . The internal vascular
structure begins at the shoulder and continues
under the arm, crosses the antecubital fossa
forearm, makes a loop in the back of the hand, and
then returns to the underarm . This venous system
is constructed of special, natural dry rubber, with
the lumen being the approximate size of an adult
human vein (See Figure 65) . This vascular structure
has inlet and outlet tubing at the shoulder . It is via
these tubes that synthetic blood is infiltrated .
Filling the Venous System and Preparing the Arm
for Blood Draws
1 . Prepare the synthetic blood by filling the
pint bottle containing the synthetic blood
concentrate with distilled water .
2 . Close the clamp on the IV tubing and pour the
synthetic blood into one of the provided fluid
supply bags . This will be IV Bag A . Fill to 500 cc
maximum .
3 . Hang IV Bag A no more than 18” (45 .72 cm)
above the level of the arm . Fluid Supply stand
shown sold separately .
4 . Attach the tubing on IV Bag A to one of the
shoulder tubes . Since this is a single tube loop
system it does not matter which tube you use .
This will now be the inlet tube .
5 . Use the second shoulder tube for draining; this
will be the outlet tube . With the outlet shoulder
tube in a basin, a sink, or attached to the second
IV Bag or IV Bag B, make sure the clamp on
the drain tube is open . If using IV Bag B, ensure
the clamp on IV Bag B is also open . Flush the
vascular system with synthetic blood by slowly
opening the clamp on IV Bag A . Allow the
system to flush with synthetic blood until the air
bubbles are no longer passing through the outlet
shoulder tubing into the basin, sink, or IV
Bag B . (See Figure 66) .
Pinch Clamp
Outlet Tubing
Inlet Tubing
Pinch
Clamp
12"
Life/form
®
Blood
Venous System
Anterior
Posterior
Needle
Adapter
Posterior
Anterior
Fig 65.
Fig 66.
A
6 . Close the clamp on the outlet shoulder tube and,
if using IV Bag B to close off the blood outlet, the
system is now filled and pressurized . Be sure to
leave the clamp on IV Bag A open .
The arm is ready to practice drawing blood .
Synthetic blood can be drawn anywhere along the
pathway of the vein .
25