11
INSTALLATION AND OPERATING
INSTRUCTIONS
NARVI BASIC
EN
Please read the manual carefully before you start installing and using it and keep the manual for future
reference. The products are meant only to be used as a electrical sauna heater controller.
1. THE ELECTRIC HEATER SET INCLUDES:
- Temperature sensor
- Control unit
Table 1.
2. INSTALLATION:
2.1 Installation instructions for the heater, the temperature sensor and the control unit
- Connection of the sauna heater to the power supply may only be carried out by an
authorised electrician in accordance with the valid regulations.
- A rubber-sheathed cable of type H07RN-F or similar must be used as the connection cable.
- If you want to make use of the temperature control feature, we recommend using a rubber cable
with at least seven wires. The cross-section of the cable and the fuse size are presented in Table 1.
2.11 Connection the power supply cable
- Install control unit as shown in figure 1 and 2.
- Connect the power cable. Do not connect voltage to the heater
before adding the temperature sensor and the controller.
min 800
max 600
100 mm
195 mm
140 mm
59 mm
min 800
max 600
100 mm
195 mm
140 mm
59 mm
Figure 1.
Figure 2.
Capacity
400 V 3N~
Fuses
kW
mm
2
A
4,5
5 x 1,5
3 x 10
6,0
5 x 1,5
3 x 10
6,8
5 x 1,5
3 x 10
9,0
5 x 2,5
3 x 16
10,5
5 x 2,5
3 x 16
min 800
max 600
100 mm
195 mm
140 mm
59 mm