INSTRUCTIONS BOOK FOR FURNACE H2
6
1.6. Description of elements
1.6.1. Openings
The furnace has three openings:
- The front opening is the one usually used, since it is the widest.
- Side openings are used to heat longer bars. If we want to heat a larger length of bar we will open only a
lateral opening. If we want to heat an intermediate part of the bar we will open the two lateral openings of the
oven so that the bar can pass through the inside of the oven and thus be able to heat the desired part
Picture 2. Furnace openings
1.6.2. Burners
The burners of Nargesa’s Furnaces has been manufactured by Nargesa and designed exclusively to be used
on the furnaces H1, H2 and H3.
- Type of burner: Athmospheric
- Maximum supply pressure: 1,5 Bar
- Fuel: Propane gas GLP
- Power: 4 Kw
Picture 3. Furnace burner