SECTION I: USER’S INFORMATION

SAFETY

1.

The furnace area must be kept clear and free of combustible mate-
rials, gasoline and other flammable vapors and liquids.

2.

Insulating materials may be combustible. The furnace must be
kept free and clear of insulating materials. The furnace area must
be examined when installed in an attic or other insulated space or
when insulation is added to be sure that the insulation material has
been kept away from the furnace.

3.

The furnace needs air for combustion in order to operate properly
and safely. Do not block or obstruct air openings on the furnace,
air openings to the area where the furnace is installed, or spaces
around the furnace.

4.

Follow the instructions exactly as shown on the OPERATING
INSTRUCTION LABEL or the Start-up and Shutdown Instructions
on Page 3 of this manual when lighting the furnace or turning the
furnace off.

5.

Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical
supply.

6.

Do not use this furnace if any part has been under water. A flood-
damaged furnace is extremely dangerous. Attempts to use the fur-
nace can result in fire or explosion. A qualified service agency
should be contacted to inspect the furnace and replace all gas
controls, control system parts, electrical parts that have been wet
or the furnace if deemed necessary.

FIRE OR EXPLOSION HAZARD - 

Failure to follow safety

warnings exactly could result in serious injury, death, or prop-
erty damage.

— 

Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other
appliance.

—  

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone 
(including cell phone) in your building.

Leave the building immediately.

Immediately call your gas supplier from a neighbor’s 
phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire depart-
ment.

— 

 Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

CONTACT INFORMATION

Go to website at www.york.com click on “contact”, then click on “contact form” and follow the instructions.

Contact us by mail:

York International

Consumer Relations

5005 York Drive

Norman, OK 73069

TABLE OF CONTENTS

CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

USER’S INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

SAFETY   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTRUCTIONS FOR EXAMINING THE FURNACE 
INSTALLATION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
HOW YOUR GAS FURNACE WORKS   . . . . . . . . . . . . . . . . . . . . . . 3
START-UP AND SHUTDOWN INSTRUCTIONS  . . . . . . . . . . . . . . . 3
FURNACE USER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . 4

SERVICE AND MAINTENANCE MANUAL . . . . . . . . . . . . . . . . . . . . . 5

SAFETY SECTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
FURNACE MAINTENANCE SECTION . . . . . . . . . . . . . . . . . . . . . . . 5
SEQUENCE OF OPERATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CFM / TIMER BOARD   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

HEATING AIRFLOW  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
COOLING AIRFLOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
DIRECT DRIVE BLOWER MOTOR   . . . . . . . . . . . . . . . . . . . . . . . . .7
INSTALLATION OF PSC MOTOR:  . . . . . . . . . . . . . . . . . . . . . . . . . .7
FURNACE CLEANING SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . .8
TROUBLESHOOTING   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
FURNACE DIAGNOSTICS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

REPLACEMENT PARTS LIST   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

FIELD INSTALLED ACCESSORIES - NON-ELECTRICAL   . . . . . .13

REPLACEMENT PART CONTACT INFORMATION . . . . . . . . . . . . .13
WIRING DIAGRAM   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

LIMITED WARRANTY   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Summary of Contents for P XD-V Series

Page 1: ...e fur nace can result in fire or explosion A qualified service agency should be contacted to inspect the furnace and replace all gas controls control system parts electrical parts that have been wet o...

Page 2: ...ng making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure it is physically sound without cracks gaps or sagging and has a good seal 5 Examine the...

Page 3: ...e control system and any gas control which has been under water Operating Instructions 1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electric power...

Page 4: ...lter after cleaning you must do the following 1 Slide filter into place 2 Snap the door on or place the door in position and tighten the retaining screws if provided 3 Make sure the door is secure to...

Page 5: ...iliary Limit and Roll out Switches for closed contacts The Control checks that the Low Fire Pressure Switch 1LP is open The Inducer Motor is energized on high speed closing the con tacts of 1LP The Co...

Page 6: ...provide the highest CFM Pin Position B and C are the medium and medium low CFM settings Pin Position D will provide the lowest CFM Refer to Table 16 in the installation manual for the proper HEAT Tap...

Page 7: ...s were not previously removed also remove and discard these two screws located on each front corner of the blower assembly 3 Loosen the blower wheel set screw that secures the blower wheel to the blow...

Page 8: ...the conden sate drain pan Remove the vent blower housing blower and the condensate pan The turbulators can then be gently removed from the secondary heat exchanger 3 Using a stiff wire brush remove t...

Page 9: ...by the control Effect Control tries 3 times then goes into Soft Lockout There is a 1 minute delay after a failed ignition attempt 7 seconds is added to the igniter warm up time after a failed ignitio...

Page 10: ...W INDUCER LOW STAGE PRESSURE SWITCH HSI 1ST STAGE MAIN VALVE FLAME SENSE LOW CIRCULATOR HEAT SPEED 1ST STAGE LOW PRESSURE SWITCH CLOSE RECOGNITION HSI WARM UP 17 SEC IGNITION ACTIVATION PERIOD 4 SEC T...

Page 11: ...itary Products Group 11 SECTION III REPLACEMENT PARTS LIST 15 16 1 17 3 7A 13 14 5 8 12 9 2 7 6 6 11 6A 24 27 26 35 38 34 32 33 25 36 22 37 21 20 28 29 23 31 30 18 19 51 63 43 53 59 57 58 55 39 41 52...

Page 12: ...R BURNER BOX 31 COVER HEAT EXCHANGER 32 PANEL FRONT Blower 33 PANEL FRONT Burner 34 PANEL TOP 35 SUPPORT BURNER 36 WRAPPER CABINET 37 PANEL VESTIBULE Lower 38 PLUG WINDOW CLEAR 875 MISCELLANEOUS 39 CO...

Page 13: ...SWITCH KIT DOES NOT INCLUDE ORIFICES FOR APPLICATION INFORMATION SEE FORM 035 14460 000 CONDENSATE NEUTRALIZER KIT ALL MODELS REPLACEMENT PART CONTACT INFORMATION This is a generic parts list To requ...

Page 14: ...035 19643 001 Rev B 0204 14 Unitary Products Group SECTION IV WIRING DIAGRAM FIGURE 10 Wiring Diagram...

Page 15: ...035 19643 001 Rev B 0204 Unitary Products Group 15 NOTES...

Page 16: ...lies only to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation installation or...