INSTRUCTIONS BOOK FOR FURNACE H2
19
5.4. Setting up
Before putting the furnace into operation, all the elements will be connected:
- Connect the
Gas hose
to the
Gas inlet fitting
. Threading the hose with the
Fitting
until you feel the pressure
of the flat gasket.
- Connect the
Pressure regulator
to an
Adapter
for the gas cylinder. This adapter is not supplied with the fur-
nace , as this element is different in each country.
- Verify that the maximum gas inlet pressure is less than 25 bars.
- Connect the Adapter to a LPG propane gas cylinder
5.5. Openings
There are two side openings to work with longer materials.
To remove the
Doors,
move the
Lock up
and pull the
Door
out of position. Leave the Closure in its original
position.
To place the
Side door,
move the
Latch upwards
and place the
Door
in the lateral opening, press until it stops
and lower the
Latch
to its original position.
WARNING:
To manipulate the
Side doors
it is necessary to turn off the
Burners
and wait 24 hours
to make sure that the insulating material is at room temperature
The
Pressure Regulator
and
Gas Hose
supplied by Nargesa will always be used
Summary of Contents for H2
Page 2: ...Thanks for choosing our brand www nargesa com...
Page 25: ...Tecnichal Annex Furnace H2 List of parts Location of components Gas layout...
Page 27: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 3...
Page 28: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 4...
Page 29: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 5...
Page 30: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 6...
Page 31: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 7...
Page 32: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 8 Location of components...
Page 33: ...MANUAL DE INSTRUCCIONES DEL HORNO H2 A 9 Gas layout...