MAX
H1+H2+V
MIN
H1+H2+V
MAX D
MAX
ELBOWS
65 FEET
10 FEET
8 FEET
SIX 90°
DOWNWARD VERTICAL VENTING
Restrictor Plate Installation
If the Continuous Pilot Ignition feature is activated, the power
vent blower will also activate.
note:
Dilution Plate Installation
Under certain situations (longer vents), it may be necessary to add a dilution plate to the bottom portion of the gas power
vent.
Certain installations may display a very active fl ame. If this appearance is not desirable, the vent exit may be restricted using
a restrictor vent kit. This will reduce the velocity of the exhaust gases, slowing down the fl ame pattern and creating a more
traditional gentle fl ame appearance. Specifi c instructions are included with the kit.
W415-4076 / A / 03.08.22
Multi-elbow installations are possible up to a maximum of six 90°.
MAX
V1+V2+V3+
H1+H2+H3
MIN
V1+V2+V3+
H1+H2+H3
MAX
ELBOWS
65 FEET
10 FEET
SIX 90°
MULTI ELBOW