www.napoleongrills.com
54
Leak Testing Instructions
WARNING!
A leak test must be performed annually and each time a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks or open flames
are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Leak testing
: This must be done before initial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak
Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Care department and have the grill inspected by a certified gas
installer.
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill
inspected by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
Natural Gas Only
Propane Only
Summary of Contents for PRO665
Page 44: ...www napoleongrills com 44 3 8 10mm 3 x N570 0086 14 x 1 2 1 2 FRONT REAR AVANT ARRIÈRE ...
Page 45: ...www napoleongrills com 45 1 2 3 4 ...
Page 47: ...www napoleongrills com 47 ...
Page 48: ...www napoleongrills com 48 ...
Page 49: ...www napoleongrills com 49 Disposable grease tray Récipient à graisse jetable ...
Page 65: ...www napoleongrills com 65 NOTES ...
Page 66: ...www napoleongrills com 66 NOTES ...
Page 67: ...www napoleongrills com 67 NOTES ...
Page 68: ...N415 0305 ...