W415-1501 / 05.15.15
7
EN
2.3 GENERAL
INFORMATION
2.3.1 FEATURES
Shipped with appliance:
Shipped with faceplate:
Installation
manual
Faceplate
Baffl
e
12
faceplate
screws
Ember
Strip
Log
Retainer
Shipped with the door(s):
Flex duct w/ start collar 10' (3m) length, 6" (152mm)
Installation instructions and hardware
diameter (1 for NZ150-KT or blower kit and 2 for
outside combustion air supplies).
Approximate Heating Capacity up to 3,000 square feet (279 square meters) (Will vary with the home's fl oor
plan, insulation and outside temperature).
Maximum burning time up to 14 hours.
BTU Output per hour 10,000 to 80,000 (cord wood method).
The blower on "HIGH" draws 2.2 amps on 120 volts A.C. (Approximately 250 watts).
CALIFORNIA PROP 65 WARNING:
Use of this product may produce smoke which contains
chemicals known to the State of California to cause can-
cer, birth defects, or other reproductive harm.
Do not use makeshift compromises during installation.
Do not block or restrict air, grille or louvre openings! Do
not add a hood.
Burning your appliance with the door open or ajar creates a fi re hazard that may result in a house and/or
chimney fi re.
All venting connections must be in compliance with the chimney manufacturers installation instructions.
Clearances referred to throughout this manual are the minimum requirements.
Your appliance must be installed in accordance with all national and local building code standards and
the standard of Chimney and Appliances, Vents and Solid Fuel Burning Appliances NFPA #211. Consult
the authority having jurisdiction (such as municipal building department, fi re department, fi re prevention
bureau, etc.) to determine the need to obtain a permit. If you are in doubt about the proper installation for
your situation, contact your dealer or local building or fi re offi cial. The manufacturer does not guarantee
that this appliance and its options will completely heat your entire home.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
It is recommended that in all cases, the appliance be secured to the fl oor. Use the pallet packing brackets
to accomplish this.
This appliance has been certifi ed EPA exempt
.
•
Maximum log length of 32" (813mm)
•
Long burn time - up to 14 hours
•
Optional 320 CFM blower for convection heat
•
Thermostat for automatic control of the blower
• Large
fi rebox capacity - 4.8 cu. ft. (0.1 cu. m.)
•
Large glass doors for maximum visibility
•
Firebrick lining for fi rebox protection
•
Outside air for combustion
DO NOT LET THE APPLIANCE BECOME HOT ENOUGH FOR ANY PART TO GLOW RED.
2.3.2 HEATING SPECIFICATIONS
2.3.3 ELECTRICAL SPECIFICATIONS
2.3.4 PACKING LIST
2.3.5 EPA COMPLIANCE