W415-0369 / F / 12.10.07
SYMPTOM
PROBLEM
TEST SOLUTION
Remote wall switch
is in “OFF” position;
main burner comes
on when gas knob
is turned to “ON”
position.
Wall switch is mounted upside
down
- reverse.
Faulty valve.
- replace.
- replace.
Remote wall switch is ground-
ing.
- check for ground (short); repair ground or replace wire.
Remote wall switch wire is
grounding.
Carbon is being
deposited on, logs or
combustion chamber
surfaces.
Flame is impinging on the logs
or combustion chamber.
- check that the logs are correctly positioned.
- open air shutter to increase the primary air.
- check the input rate: check the manifold pressure and orifi ce size as speci-
fi ed by the rating plate values.
- close mesh screens.
Air shutter has become blocked
- ensure air shutter opening is free of lint or other obstructions.